// CODE SNIPPET
5.4.3.3.2 Vestibule Size
Go To Full Code Chapter
Vestibules shall be designed so that in passing through the vestibule it is not necessary for the interior and exterior doors to open at the same time. Interior and exterior doors shall have a minimum distance between them of not less than 7 ft when in the closed position. The floor area of each vestibule shall not exceed the greater of 50 ft2 or 2% of the gross conditioned floor area for that level of the building.
Related Code Sections
5.4.3.3.2 Building Envelope, Vestibule Size
Vestibules shall be designed so that in passing through the vestibule it is not necessary for the interior and exterior doors to open at the same ...
909.20.4.2.1 Fire Protection and Life Safety Systems, Engineered Ventilation System
vestibule in the emergency operation mode and shall be sized to handle three vestibules simultaneously. Smoke detectors shall be located at the floor-side ...
909.20.4.1 Fire Protection and Life Safety Systems, Vestibule Doors
The door assembly from the building into the vestibule shall be a fire door assembly complying with Section 716.2.2.1. The door assembly from ...
909.20 Fire Protection and Life Safety Systems, Smokeproof Enclosures
air changes per hour from any vestibule in the emergency operation mode and shall be sized to handle three vestibules simultaneously. Smoke detectors ...
5.4.3.3 Building Envelope, Vestibules and Revolving Doors
Vestibules and revolving doors shall be installed in accordance with this section.
Exceptions to 5.4.3.3
Doors not intended to be used ...