1615.4.2.4 Vertical Ties
JUMP TO FULL CODE CHAPTER
Vertical ties shall consist of continuous or spliced reinforcing, continuous or spliced members, wall sheathing or other engineered systems. Vertical tension ties shall be provided in bearing walls and shall be continuous over the height of the building. The minimum nominal tensile strength for vertical ties within a bearing wall shall be equal to the weight of the wall within that story plus the weight of the diaphragm tributary to the wall in the story below. No fewer than two ties shall be provided for each wall. The strength of each tie need not exceed 3,000 pounds per foot (450 kN/m) of wall tributary to the tie for walls of masonry construction or 750 pounds per foot (140 kN/m) of wall tributary to the tie for walls of cold-formed steel light-frame construction.
Related Code Sections
1615.4.2.4 Structural Design, Vertical Ties
Vertical ties shall consist of continuous or spliced reinforcing, continuous or spliced members, wall sheathing or other engineered systems. Vertical ...
Building Code 2015 of Utah > 16 Structural Design > 1615 Structural Integrity > 1615.4 Bearing Wall Structures > 1615.4.2 Other Bearing Wall Structures > 1615.4.2.4 Vertical Ties
1616.3.2.4 Structural Design, Vertical Ties
Vertical ties shall consist of continuous or spliced reinforcing, continuous or spliced members, wall sheathing or other engineered systems. Vertical ...
Building Code 2018 of Utah > 16 Structural Design > 1616 Structural Integrity > 1616.3 Bearing Wall Structures > 1616.3.2 Other Bearing Wall Structures > 1616.3.2.4 Vertical Ties
Section AE605 Manufactured Housing Used as Dwellings, Ties, Materials and Installation
nearest that end not exceeding 8 feet (2438 mm). When continuous straps are provided as vertical ties, such ties shall be positioned at rafters and studs ...
Residential Code 2015 of Utah > E Manufactured Housing Used as Dwellings > AE605 Ties, Materials and Installation
1615.4.2 Structural Design, Other Bearing Wall Structures
Vertical ties shall consist of continuous or spliced reinforcing, continuous or spliced members, wall sheathing or other engineered systems. Vertical ...
Building Code 2015 of Utah > 16 Structural Design > 1615 Structural Integrity > 1615.4 Bearing Wall Structures > 1615.4.2 Other Bearing Wall Structures
1616.3.2 Structural Design, Other Bearing Wall Structures
-frame construction. Vertical ties shall consist ...
Building Code 2018 of Utah > 16 Structural Design > 1616 Structural Integrity > 1616.3 Bearing Wall Structures > 1616.3.2 Other Bearing Wall Structures