• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.703(c) Vertical Slip Forms

OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.703 Requirements for Cast-In-Place Concrete > 1926.703(c) Vertical Slip Forms
JUMP TO FULL CODE CHAPTER

1926.703(c)(1)

The steel rods or pipes on which jacks climb or by which the forms are lifted shall be -

1926.703(c)(1)(i)

Specifically designed for that purpose; and

1926.703(c)(1)(ii)

Adequately braced where not encased in concrete.

1926.703(c)(2)

Forms shall be designed to prevent excessive distortion of the structure during the jacking operation.

1926.703(c)(3)

All vertical slip forms shall be provided with scaffolds or work platforms where employees are required to work or pass.

1926.703(c)(4)

Jacks and vertical supports shall be positioned in such a manner that the loads do not exceed the rated capacity of the jacks.

1926.703(c)(5)

The jacks or other lifting devices shall be provided with mechanical dogs or other automatic holding devices to support the slip forms whenever failure of the power supply or lifting mechanism occurs.

1926.703(c)(6)

The form structure shall be maintained within all design tolerances specified for plumbness during the jacking operation.

1926.703(c)(7)

The predetermined safe rate of lift shall not be exceeded.

Related Code Sections


1926.700(b)(8) Concrete and Masonry Construction, Vertical Slip Forms
Vertical slip forms means forms which are jacked vertically during the placement of concrete ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.700 Scope, Application, and Definitions Applicable to This Subpart > 1926.700(b) Definitions Applicable to This Subpart > 1926.700(b)(8) Vertical Slip Forms
1926.703(c) Concrete and Masonry Construction, Vertical Slip Forms
All vertical slip forms shall be provided with scaffolds or work ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.703 Requirements for Cast-In-Place Concrete > 1926.703(c) Vertical Slip Forms
1926.703(c)(1) Concrete and Masonry Construction,
The steel rods or pipes on which jacks climb or by which the forms are lifted shall ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.703 Requirements for Cast-In-Place Concrete > 1926.703(c) Vertical Slip Forms > 1926.703(c)(1)
1926.703(c)(1)(i) Concrete and Masonry Construction,
Specifically designed for that purpose ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.703 Requirements for Cast-In-Place Concrete > 1926.703(c) Vertical Slip Forms > 1926.703(c)(1) > 1926.703(c)(1)(i)
1926.703(c)(1)(ii) Concrete and Masonry Construction,
Adequately braced where not encased in concrete ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.703 Requirements for Cast-In-Place Concrete > 1926.703(c) Vertical Slip Forms > 1926.703(c)(1) > 1926.703(c)(1)(ii)
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE