3308.3 Vertical Safety Netting Requirements
JUMP TO FULL CODE CHAPTER
Vertical safety netting shall consist of a vertical system of nets and their supports that meet requirements set forth in department rules. Vertical safety netting shall be of a fine mesh of a size and strength sufficient to contain falling tools and materials. Wall opening screens, grills or tarpaulins may be used in lieu of vertical safety netting, provided that they shall be of such construction and mounting as to retain debris.
On every story where vertical safety netting is required, it shall extend from the floor to a height of not less than 60 inches (1524 mm). Vertical safety nets and their components shall also meet the requirements set forth in rules promulgated by the commissioner.
Related Code Sections
3308.3 Safeguards During Construction or Demolition, Vertical Safety Netting Requirements
Vertical safety netting shall consist of a vertical system of nets and their supports that meet requirements set forth in department rules. Vertical ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3308 Safety Netting > 3308.3 Vertical Safety Netting Requirements
3308.5 Safeguards During Construction or Demolition, Vertical Safety Netting Systems
that no work, other than steel erection or metal deck placement, is occurring on that story.
Vertical safety netting is not required at a location ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3308 Unenclosed Perimeter Protection > 3308.5 Vertical Safety Netting Systems
3308.5 Safeguards During Construction or Demolition, Vertical Safety Netting Systems
has not been poured.
Vertical safety netting is not required at a level where a supported scaffold covers the full width of the unenclosed ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3308 Protection of Unenclosed Perimeters > 3308.5 Vertical Safety Netting Systems
3308.2 Safeguards During Construction or Demolition, Permit
A permit is required for the installation of unenclosed perimeter protection.
Exceptions: A permit is not required for:
Vertical safety ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3308 Unenclosed Perimeter Protection > 3308.2 Permit
3314.9.4 Safeguards During Construction or Demolition, Supported Scaffolds at the Edge
to prevent dislodgement by wind or accidental impact. Exception: The above requirements shall not apply where vertical safety netting that meets ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.9 Supported Scaffold > 3314.9.4 Supported Scaffolds at the Edge