• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1401.6.6.1 Vertical Opening Formula

Existing Building Code 2015 of New York State > 14 Performance Compliance Methods > 1401 General > 1401.6 Evaluation Process > 1401.6.6 Vertical Openings > 1401.6.6.1 Vertical Opening Formula
JUMP TO FULL CODE CHAPTER
The following formula shall be used in computing vertical opening value.



where:

VO = Vertical opening value.
PV = Protection value from Table 1401.6.6.(1).
CF = Construction-type factor from Table 1401.6.6.(2).

Related Code Sections


1301.6.6.1 Performance Compliance Methods, Vertical Opening Formula
The following formula shall be used in computing vertical opening value. VO = PV × CF (Equation 13-5) where: VO = Vertical ...
2010 Existing Building Code of NY > 13 Performance Compliance Methods > 1301 General > 1301.6 Evaluation Process > 1301.6.6 Vertical Openings > 1301.6.6.1 Vertical Opening Formula
1301.6.6.1 Performance Compliance Methods, Vertical Opening Formula
The following formula shall be used in computing vertical opening value. (Equation 13-5) where: VO = Vertical opening value. The ...
2020 Existing Building Code of NYS > 13 Performance Compliance Methods > 1301 General > 1301.6 Evaluation Process > 1301.6.6 Vertical Openings > 1301.6.6.1 Vertical Opening Formula
1401.6.6.1 Performance Compliance Methods, Vertical Opening Formula
The following formula shall be used in computing vertical opening value. where: VO = Vertical opening value. PV ...
Existing Building Code 2015 of New York State > 14 Performance Compliance Methods > 1401 General > 1401.6 Evaluation Process > 1401.6.6 Vertical Openings > 1401.6.6.1 Vertical Opening Formula
402.8.2.1 Special Detailed Requirements Based on Use and Occupancy, Occupant Formula
on gross leasable area of the covered or open mall building (excluding anchor buildings ) and the occupant load factor as determined by Equation 4-1 ...
Building Code 2015 of New York State > 4 Special Detailed Requirements Based on Use and Occupancy > 402 Covered Mall and Open Mall Buildings > 402.8 Means of Egress > 402.8.2 Determination of Occupant Load > 402.8.2.1 Occupant Formula
402.8.2.1 Special Detailed Requirements Based on Occupancy and Use, Occupant Formula
on gross leasable area of the covered or open mall building (excluding anchor buildings ) and the occupant load factor as determined by Equation 4-1 ...
2020 Building Code of New York State > 4 Special Detailed Requirements Based on Occupancy and Use > 402 Covered Mall and Open Mall Buildings > 402.8 Means of Egress > 402.8.2 Determination of Occupant Load > 402.8.2.1 Occupant Formula
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE