208.2.4 Vertical Clearance at Parking Spaces
Related Code Sections
208.2.4 Scoping Requirements, Vertical Clearance at Parking Spaces
For every six or fraction of six parking spaces required by 208.2 to comply with 502, at least one shall have a vertical clearance complying ...
2018 Illinois Accessibility Code > 2 Scoping Requirements > 208 Parking Spaces > 208.2 Minimum Number > 208.2.4 Vertical Clearance at Parking Spaces
1106.5 Accessibility, Van Spaces
For every six or fraction of six accessible parking spaces, at least one shall be a van-accessible parking space. Exception: In Group U private ...
Building Code 2018 of Illinois > 11 Accessibility > 1106 Parking and Passenger Loading Facilities > 1106.5 Van Spaces
502.5 General Site and Building Elements, Vertical Clearance
Parking spaces required by 208.2.4 , and access aisles and vehicular routes serving them, shall provide a vertical clearance of 98 inches (2490 mm ...
2018 Illinois Accessibility Code > 5 General Site and Building Elements > 502 Parking Spaces > 502.5 Vertical Clearance
503.5 General Site and Building Elements, Vertical Clearance
loading zone to a vehicular exit shall provide a vertical clearance of 114 inches (2895 mm) minimum ...
2018 Illinois Accessibility Code > 5 General Site and Building Elements > 503 Passenger Loading Zones > 503.5 Vertical Clearance
307.4 Building Blocks, Vertical Clearance
Vertical clearance shall be 80 inches (2030 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less ...
2018 Illinois Accessibility Code > 3 Building Blocks > 307 Protruding Objects > 307.4 Vertical Clearance