2304.12.2.6 Ventilation Beneath Balcony or Elevated Walking Surfaces
JUMP TO FULL CODE CHAPTER
Enclosed framing in exterior balconies and elevated walking surfaces that are exposed to rain, snow or drainage from irrigation shall be provided with openings that provide a net free cross-ventilation area not less than 1/150 of the area of each separate space.
Related Code Sections
2304.12.2.6 Wood, Ventilation Beneath Balcony or Elevated Walking Surfaces
Enclosed framing in exterior balconies and elevated walking surfaces that are exposed to rain, snow or drainage from irrigation shall be provided ...
Building Code 2018 of Utah > 23 Wood > 2304 General Construction Requirements > 2304.12 Protection Against Decay and Termites > 2304.12.2 Other Locations > 2304.12.2.6 Ventilation Beneath Balcony or Elevated Walking Surfaces
106.2.5 Scope and Administration, Exterior Balconies and Elevated Walking Surfaces
Where the scope of work involves balconies or other elevated walking surfaces exposed to water from direct or blowing rain, snow or irrigation ...
Existing Building Code 2018 of Utah > 1 Scope and Administration > 106 Construction Documents > 106.2 Construction Documents > 106.2.5 Exterior Balconies and Elevated Walking Surfaces
107.2.5 Scope and Administration, Exterior Balconies and Elevated Walking Surfaces
Where balconies or other elevated walking surfaces are exposed to water from direct or blowing rain, snow, or irrigation, and the structural framing ...
Building Code 2018 of Utah > 1 Scope and Administration > 107 Submittal Documents > 107.2 Construction Documents > 107.2.5 Exterior Balconies and Elevated Walking Surfaces
110.3.6 Scope and Administration, Weather-Exposed Balcony and Walking Surface Waterproofing
Where balconies or other elevated walking surfaces are exposed to water from direct or blowing rain, snow or irrigation, and the structural framing ...
Building Code 2018 of Utah > 1 Scope and Administration > 110 Inspections > 110.3 Required Inspections > 110.3.6 Weather-Exposed Balcony and Walking Surface Waterproofing
109.3.6 Scope and Administration, Weather-Exposed Balcony and Walking Surface Waterproofing
Where the scope of work involves balconies or other elevated walking surfaces exposed to water from direct or blowing rain, snow or irrigation ...
Existing Building Code 2018 of Utah > 1 Scope and Administration > 109 Inspections > 109.3 Required Inspections > 109.3.6 Weather-Exposed Balcony and Walking Surface Waterproofing