[F] 421.4.1.1 Ventilation Alternative
JUMP TO FULL CODE CHAPTER
Where an exhaust system is used in lieu of the interlock system required by Section 421.4.1, exhaust ventilation systems shall operate continuously and shall be designed to operate at a negative pressure in relation to the surrounding area. The average velocity of ventilation at the face of the door opening with the door in the fully open position shall not be less than 60 feet per minute (0.3048 m/s) and not less than 45 feet per minute (0.2287 m/s) at any point in the door opening.
Related Code Sections
421.4.1.1 Special Detailed Requirements Based on Use and Occupancy, Ventilation Alternative
Where an exhaust system is used in lieu of the interlock system required by Section 421.4.1, exhaust ventilation systems shall operate continuously ...
Building Code 2012 of South Holland > 4 Special Detailed Requirements Based on Use and Occupancy > 421 Hydrogen Cutoff Rooms > 421.4 Design and Construction > 421.4.1 Opening Protectives > 421.4.1.1 Ventilation Alternative
909.20.3 Fire Protection Systems, Natural Ventilation Alternative
The provisions of Sections 909.20.3.1 through 909.20.3.3 shall apply to ventilation of smokeproof enclosures by natural means ...
Building Code 2012 of South Holland > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.20 Smokeproof Enclosures > 909.20.3 Natural Ventilation Alternative
909.20.3 Fire Protection and Life Safety Systems, Natural Ventilation Alternative
The provisions of Sections 909.20.3.1 through 909.20.3.3 shall apply to ventilation of smokeproof enclosures by natural means ...
Building Code 2018 of South Holland > 9 Fire Protection and Life Safety Systems > 909 Smoke Control Systems > 909.20 Smokeproof Enclosures > 909.20.3 Natural Ventilation Alternative
909.20.4.2.1 Fire Protection and Life Safety Systems, Engineered Ventilation System
Where a specially engineered system is used, the system shall exhaust a quantity of air equal to not less than 90 air changes per hour from any ...
Building Code 2018 of South Holland > 9 Fire Protection and Life Safety Systems > 909 Smoke Control Systems > 909.20 Smokeproof Enclosures > 909.20.4 Mechanical Ventilation Alternative > 909.20.4.2 Vestibule Ventilation > 909.20.4.2.1 Engineered Ventilation System
909.20.3.3 Fire Protection and Life Safety Systems, Vestibule Ventilation
Each vestibule shall have a minimum net area of 16 square feet (1.5 m 2 ) of opening in a wall facing an outer court, yard or public way ...
Building Code 2018 of South Holland > 9 Fire Protection and Life Safety Systems > 909 Smoke Control Systems > 909.20 Smokeproof Enclosures > 909.20.3 Natural Ventilation Alternative > 909.20.3.3 Vestibule Ventilation