M2203.5 Vent Termination
JUMP TO FULL CODE CHAPTER
Vent piping shall terminate outside of buildings at a point not less than 2 feet (610 mm), measured vertically or horizontally, from any building opening. Outer ends of vent piping shall terminate in a weather-proof cap or fitting having an unobstructed area equal to or greater than the cross-sectional area of the vent pipe, and shall be located sufficiently above the ground to avoid being obstructed by snow and ice.
Related Code Sections
Section 903 Vents, Vent Terminals
Open vent pipes that extend through a roof shall be terminated not less than [NUMBER] inches (mm) above the roof. Where a roof is to be used ...
904.3 Vents, Vent Termination
Vent stacks or stack vents shall terminate outdoors to the open air or to a stack-type air admittance valve in accordance with Section 918 ...
M2203.5 Special Piping and Storage Systems, Vent Termination
Vent piping shall terminate outside of buildings at a point not less than 2 feet (610 mm), measured vertically or horizontally, from any building ...
Residential Code 2018 of Kansas > 22 Special Piping and Storage Systems > M2203 Installation > M2203.5 Vent Termination
Section P3103 Vents, Vent Terminals
Vent pipes terminating outdoors shall be extended to the outdoors through the roof or a sidewall of the building in accordance with one ...
503.6.5 Chimneys and Vents, Gas Vent Terminations
A gas vent shall terminate in accordance with one of the following: Gas vents that are 12 inches (305 mm) or less in size and located not less than ...
Fuel Gas Code 2018 of Kansas > 5 Chimneys and Vents > 503 (IFGS) Venting of Appliances > 503.6 Gas Vents > 503.6.5 Gas Vent Terminations