• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

M2203.5 Vent Termination

Residential Code 2018 of Kansas > 22 Special Piping and Storage Systems > M2203 Installation > M2203.5 Vent Termination
JUMP TO FULL CODE CHAPTER
Vent piping shall terminate outside of buildings at a point not less than 2 feet (610 mm), measured vertically or horizontally, from any building opening. Outer ends of vent piping shall terminate in a weather-proof cap or fitting having an unobstructed area equal to or greater than the cross-sectional area of the vent pipe, and shall be located sufficiently above the ground to avoid being obstructed by snow and ice.

Related Code Sections


Section 903 Vents, Vent Terminals
Open vent pipes that extend through a roof shall be terminated not less than [NUMBER] inches (mm) above the roof. Where a roof is to be used ...
Plumbing Code 2018 of Kansas > 9 Vents > 903 Vent Terminals
904.3 Vents, Vent Termination
Vent stacks or stack vents shall terminate outdoors to the open air or to a stack-type air admittance valve in accordance with Section 918 ...
Plumbing Code 2018 of Kansas > 9 Vents > 904 Outdoor Vent Extensions > 904.3 Vent Termination
M2203.5 Special Piping and Storage Systems, Vent Termination
Vent piping shall terminate outside of buildings at a point not less than 2 feet (610 mm), measured vertically or horizontally, from any building ...
Residential Code 2018 of Kansas > 22 Special Piping and Storage Systems > M2203 Installation > M2203.5 Vent Termination
Section P3103 Vents, Vent Terminals
Vent pipes terminating outdoors shall be extended to the outdoors through the roof or a sidewall of the building in accordance with one ...
Residential Code 2018 of Kansas > 31 Vents > P3103 Vent Terminals
503.6.5 Chimneys and Vents, Gas Vent Terminations
A gas vent shall terminate in accordance with one of the following: Gas vents that are 12 inches (305 mm) or less in size and located not less than ...
Fuel Gas Code 2018 of Kansas > 5 Chimneys and Vents > 503 (IFGS) Venting of Appliances > 503.6 Gas Vents > 503.6.5 Gas Vent Terminations
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING