• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1002.1 Vent Pipes

California Plumbing Code 2016 > 10 Traps and Interceptors > 1002.0 Traps Protected by Vent Pipes > 1002.1 Vent Pipes
JUMP TO FULL CODE CHAPTER
Each plumbing fixture trap, except as otherwise provided in this code, shall be protected against siphonage, backpressure, and air circulation shall be assured throughout the drainage system by means of a vent pipe installed in accordance with the requirements of this code.

Related Code Sections


1002.1 Traps and Interceptors, Vent Pipes
be assured throughout the drainage system using a vent pipe installed in accordance with the requirements of this code ...
California Plumbing Code 2019 > 10 Traps and Interceptors > 1002.0 Traps Protected by Vent Pipes > 1002.1 Vent Pipes
1002.1 Traps and Interceptors, Vent Pipes
be assured throughout the drainage system by means of a vent pipe installed in accordance with the requirements of this code ...
California Plumbing Code 2016 > 10 Traps and Interceptors > 1002.0 Traps Protected by Vent Pipes > 1002.1 Vent Pipes
1208.5.4.1 Fuel Gas Piping, Regulator Vent Piping
Plastic pipe and fittings used to connect regulator vents to remote vent terminations shall be PVC in accordance with UL 651. PVC vent piping shall ...
California Plumbing Code 2016 > 12 Fuel Gas Piping > 1208.0 Gas Piping System Design, Materials, and Components > 1208.5 Acceptable Piping Materials and Joining Methods > 1208.5.4 Plastic Pipe, Tubing, and Fittings > 1208.5.4.1 Regulator Vent Piping
1208.6.6 Fuel Gas Piping, Regulator Vent Piping
Plastic pipe and fittings used to connect regulator vents to remote vent terminations shall be PVC conforming to UL 651 (Schedule 40 and 80). PVC ...
California Plumbing Code 2019 > 12 Fuel Gas Piping > 1208.0 Gas Piping System Design, Materials, and Components > 1208.6 Acceptable Piping Materials and Joining Methods > 1208.6.6 Regulator Vent Piping
1308.5.4.1 Fuel Gas Piping, Regulator Vent Piping
Plastic pipe and fittings used to connect regulator vents to remote vent terminations shall be PVC in accordance with UL 651. PVC vent piping shall ...
California Mechanical Code 2016 > 13 Fuel Gas Piping > 1308.0 Gas Piping System Design, Materials, and Components > 1308.5 Acceptable Piping Materials and Joining Methods > 1308.5.4 Plastic Pipe, Tubing, and Fittings > 1308.5.4.1 Regulator Vent Piping
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE