// CODE SNIPPET
904.5 Vent Headers
Go To Full Code Chapter
Stack vents and vent stacks connected into a common vent header at the top of the stacks and extending to the open air at one point shall be sized in accordance with the requirements of Section 906.1. The number of fixture units shall be the sum of all fixture units on all stacks connected thereto, and the developed length shall be the longest vent length from the intersection at the base of the most distant stack to the vent terminal in the open air, as a direct extension of one stack.
Upcodes Diagrams
Related Code Sections
903.5 Vents, Vent Headers
Stack vents and vent stacks connected into a common vent header at the top of the stacks and extending to the open air at one point shall be sized ...
904.5 Vents, Vent Headers
Stack vents and vent stacks connected into a common vent header at the top of the stacks and extending to the open air at one point shall be sized ...
904.5 Vents, Vent Headers
Stack vents and vent stacks connected into a common vent header at the top of the stacks and extending to the open air at one point shall be sized ...
919.2 Vents, Individual Branch Fixture and Individual Fixture Header Vents
The maximum developed length of individual fixture vents to vent branches and vent headers shall be determined in accordance with Table 919.2 ...
919.2 Vents, Individual Branch Fixture and Individual Fixture Header Vents
The maximum developed length of individual fixture vents to vent branches and vent headers shall be determined in accordance with Table 919.2 ...