P3104.6 Vent for Future Fixtures
JUMP TO FULL CODE CHAPTER
Where the drainage piping has been roughed-in for future fixtures, a rough-in connection for a vent, not less than one-half the diameter of the drain, shall be installed. The vent rough-in shall connect to the vent system or shall be vented by other means as provided in this chapter. The connection shall be identified to indicate that the connection is a vent.
Related Code Sections
905.6 Vents, Vent for Future Fixtures
Where the drainage piping has been roughed-in for future fixtures, a rough-in connection for a vent shall be installed. The vent size shall ...
Plumbing Code 2018 of Kansas > 9 Vents > 905 Vent Connections and Grades > 905.6 Vent for Future Fixtures
P3104.6 Vents, Vent for Future Fixtures
Where the drainage piping has been roughed-in for future fixtures, a rough-in connection for a vent, not less than one-half the diameter of the drain ...
Residential Code 2018 of Kansas > 31 Vents > P3104 Vent Connections and Grades > P3104.6 Vent for Future Fixtures
704.4 Sanitary Drainage, Future Fixtures
Drainage piping for future fixtures shall terminate with an approved cap or plug ...
Plumbing Code 2018 of Kansas > 7 Sanitary Drainage > 704 Drainage Piping Installation > 704.4 Future Fixtures
710.2 Sanitary Drainage, Future Fixtures
Where provision is made for the future installation of fixtures, those provided for shall be considered in determining the required sizes of drain ...
Plumbing Code 2018 of Kansas > 7 Sanitary Drainage > 710 Drainage System Sizing > 710.2 Future Fixtures
P3005.1.5 Sanitary Drainage, Provisions for Future Fixtures
Where drainage has been roughed-in for future fixtures, the drainage unit values of the future fixtures shall be considered in determining ...
Residential Code 2018 of Kansas > 30 Sanitary Drainage > P3005 Drainage System > P3005.1 Drainage Fittings and Connections > P3005.1.5 Provisions for Future Fixtures