1926.1002(e)(1) Vehicle Weight
JUMP TO FULL CODE CHAPTER
The weight of the tractor, for purposes of this section, includes the protective frame, all fuels, and other components required for normal use of the tractor. Ballast must be added when necessary to achieve a minimum total weight of 130 lb (59 kg) per maximum power-takeoff horsepower at the rated engine speed. The weight of the front end must be at least 33 lb (15 kg) per maximum power-takeoff horsepower. In case power-takeoff horsepower is unavailable, 95 percent of net engine flywheel horsepower shall be used.
Related Code Sections
1926.1002(e)(1) Rollover Protective Structures; Overhead Protection, Vehicle Weight
The weight of the tractor, for purposes of this section, includes the protective frame, all fuels, and other components required for normal use ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(e) Test Procedure for Vehicle Overturn > 1926.1002(e)(1) Vehicle Weight
1926.1001(f)(2)(i) Rollover Protective Structures; Overhead Protection,
of the energy versus weight of vehicle (see Figure W-6 for rubber-tired self-propelled scrapers; Figure W-7 for rubber-tired front-end loaders and rubber ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1001 Minimum Performance Criteria for Rollover Protective Structures for Designated Scrapers, Loaders, Dozers, Graders, and Crawler Tractors > 1926.1001(f) Performance Requirements - > 1926.1001(f)(2) Specific Performance Requirements > 1926.1001(f)(2)(i)
1926.1001(c)(2) Rollover Protective Structures; Overhead Protection,
W-1
Means to measure
Accuracy
Deflection of ROPS, inches
±5% of deflection measured.
Vehicle ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1001 Minimum Performance Criteria for Rollover Protective Structures for Designated Scrapers, Loaders, Dozers, Graders, and Crawler Tractors > 1926.1001(c) Facilities and Apparatus > 1926.1001(c)(2)
1926.1001 Rollover Protective Structures; Overhead Protection, Minimum Performance Criteria for Rollover Protective Structures for Designated Scrapers, Loaders, Dozers, Graders, and Crawler Tractors
, inches
±5% of deflection measured.
Vehicle weight, pounds
±5% of the weight measured.
Force applied to frame ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1001 Minimum Performance Criteria for Rollover Protective Structures for Designated Scrapers, Loaders, Dozers, Graders, and Crawler Tractors
1926.1001(f)(2)(ii) Rollover Protective Structures; Overhead Protection,
The applied load must attain at least a value which is determined by multiplying the vehicle weight by the corresponding factor shown in Figure W-10 ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1001 Minimum Performance Criteria for Rollover Protective Structures for Designated Scrapers, Loaders, Dozers, Graders, and Crawler Tractors > 1926.1001(f) Performance Requirements - > 1926.1001(f)(2) Specific Performance Requirements > 1926.1001(f)(2)(ii)