• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

702.15 Vehicle Washing Facilities

Green Construction Code 2012 > 7 Water Resource Conservation, Quality and Efficiency > 702 Fixtures, Fittings, Equipment and Appliances > 702.15 Vehicle Washing Facilities
JUMP TO FULL CODE CHAPTER
Waste water from reverse osmosis water treatment systems installed in vehicle washing facilities shall discharge to the washing phase water holding tank.

Related Code Sections


702.14 Water Resource Conservation, Quality and Efficiency, Vehicle Washing Facilities
Waste water from reverse osmosis water treatment systems installed in vehicle washing facilities shall discharge to the washing phase water holding ...
Green Construction Code 2015 > 7 Water Resource Conservation, Quality and Efficiency > 702 Fixtures, Fittings, Equipment and Appliances > 702.14 Vehicle Washing Facilities
702.15 Water Resource Conservation, Quality and Efficiency, Vehicle Washing Facilities
Waste water from reverse osmosis water treatment systems installed in vehicle washing facilities shall discharge to the washing phase water holding ...
Green Construction Code 2012 > 7 Water Resource Conservation, Quality and Efficiency > 702 Fixtures, Fittings, Equipment and Appliances > 702.15 Vehicle Washing Facilities
Section 702 Water Resource Conservation, Quality and Efficiency, Fixtures, Fittings, Equipment and Appliances
phase of the wash cycle at automated vehicle wash facilities shall be collected to be reused for the washing phase. Towel and chamois washing machines ...
Green Construction Code 2015 > 7 Water Resource Conservation, Quality and Efficiency > 702 Fixtures, Fittings, Equipment and Appliances
Section 304 Use and Occupancy Classification, Business Group B
traffic control towers Ambulatory care facilities Animal hospitals, kennels and pounds Banks Barber and beauty shops ...
International Building Code 2012 > 3 Use and Occupancy Classification > 304 Business Group B
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE