• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1002(e)(7) Vehicle Overturn Test -- Sideways and Rearward

OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(e) Test Procedure for Vehicle Overturn > 1926.1002(e)(7) Vehicle Overturn Test -- Sideways and Rearward
JUMP TO FULL CODE CHAPTER

1926.1002(e)(7)(i)

The tractor shall be driven under its own power along the specified path of travel at a minimum speed of 10 mph (16 kph), or maximum vehicle speed when under 10 mph (16 kph), up the ramp as described in paragraph (d)(5) of this section to induce sideways overturn.

1926.1002(e)(7)(ii)

Rear upset shall be induced by engine power with the tractor operating in gear to obtain 3 to 5 mph (4.8 to 8 kph) at maximum governed engine rpm, preferably by driving forward directly up a minimum slope of two vertical to one horizontal. The engine clutch may be used to aid in inducing the upset.

Related Code Sections


1926.1002(e)(7) Rollover Protective Structures; Overhead Protection, Vehicle Overturn Test -- Sideways and Rearward
when under 10 mph (16 kph), up the ramp as described in paragraph (d)(5) of this section to induce sideways overturn ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(e) Test Procedure for Vehicle Overturn > 1926.1002(e)(7) Vehicle Overturn Test -- Sideways and Rearward
1926.1002(i)(2) Rollover Protective Structures; Overhead Protection, Vehicle Overturn Performance Requirements
The requirements of this paragraph (i) must be met in both side and rear overturns ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(i) Performance Requirements > 1926.1002(i)(2) Vehicle Overturn Performance Requirements
1926.1002(e)(1) Rollover Protective Structures; Overhead Protection, Vehicle Weight
The weight of the tractor, for purposes of this section, includes the protective frame, all fuels, and other components required for normal use ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(e) Test Procedure for Vehicle Overturn > 1926.1002(e)(1) Vehicle Weight
1926.1002(h)(2)(iii) Rollover Protective Structures; Overhead Protection, Impact at Side
be that structural member of the protective frame likely to hit the ground first in a sideways accidental upset. The side impact shall be applied to the side ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(h) Dynamic Test > 1926.1002(h)(2) Test Procedure > 1926.1002(h)(2)(iii) Impact at Side
1926.1433(d)(7)(ii) Cranes & Derricks in Construction,
adjacent to the operator must open outward. Sliding operator doors must open rearward ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1433 Design, Construction and Testing > 1926.1433(d) > 1926.1433(d)(7) Cabs > 1926.1433(d)(7)(ii)
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE