• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

408.3.2 Vegetative Roofs

Green Construction Code 2012 of Maryland > 4 Site Development and Land Use > 408 Heat Island Mitigation > 408.3 Roof Surfaces > 408.3.2 Vegetative Roofs
JUMP TO FULL CODE CHAPTER
Vegetative roofs, where provided in accordance with Section 408.3, shall comply with the following:
  1. All plantings shall be selected based on their hardiness zone classifications in accordance with USDA MP1475 and shall be capable of withstanding the climate conditions of the jurisdiction and the micro climate conditions of the building site including, but not limited to, wind, precipitation and temperature. Planting density shall provide foliage coverage, in the warm months, of not less than 80 percent within two years of the date of installation unless a different time period is established in the approved design. Plants shall be distributed to meet the coverage requirements. Invasive plant species shall not be planted.
  2. The engineered soil medium shall be designed for the physical conditions and local climate to support the plants and shall consist of nonsynthetic materials. The planting design shall include measures to protect the engineered soil medium until the plants are established. Protection measures include, but are not limited to, installation of pregrown vegetated mats or modules, tackifying agents, fiber blankets and reinforcing mesh. The maximum wet weight and water holding capacity of an engineered soil medium shall be determined in accordance with ASTM E 2399.
  3. Where access to the building facades is provided from locations on the perimeter of the roof, nonvegetated buffers adequate to support associated equipment and to protect the roof shall be provided.
  4. Nonvegetated clearances as required for fire classification of vegetative roof systems shall be provided in accordance with the International Fire Code.
  5. Plantings shall be capable of being managed to maintain the function of the vegetative roof as provided in the documents required by Section 904.3.

Related Code Sections


408.3.2 Site Development and Land Use, Vegetative Roofs
Vegetative roofs, where provided in accordance with Section 408.3, shall comply with the following: All plantings shall be selected based ...
Green Construction Code 2012 of Maryland > 4 Site Development and Land Use > 408 Heat Island Mitigation > 408.3 Roof Surfaces > 408.3.2 Vegetative Roofs
1507.16 Roof Assemblies and Rooftop Structures, Vegetative Roofs, Roof Gardens and Landscaped Roofs
Vegetative roofs , roof gardens and landscaped roofs shall comply with the requirements of this chapter, Section 1607.13.3 and the International ...
Building Code 2018 of Maryland > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.16 Vegetative Roofs, Roof Gardens and Landscaped Roofs
1507.16 Roof Assemblies and Rooftop Structures, Vegetative Roofs, Roof Gardens and Landscaped Roofs
Vegetative roofs , roof gardens and landscaped roofs shall comply with the requirements of this chapter, Sections 1607.12.3 and 1607.12.3.1 ...
Building Code 2015 of Maryland > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.16 Vegetative Roofs, Roof Gardens and Landscaped Roofs
1607.12.3.1 Structural Design, Vegetative and Landscaped Roofs
in accordance with ASTM E2397. The uniform design live load in unoccupied landscaped areas on roofs shall be 20 psf (0.958 kN/m 2 ). The uniform design ...
Building Code 2015 of Maryland > 16 Structural Design > 1607 Live Loads > 1607.12 Roof Loads > 1607.12.3 Occupiable Roofs > 1607.12.3.1 Vegetative and Landscaped Roofs
1607.13.3.1 Structural Design, Vegetative and Landscaped Roofs
in accordance with Section 3.1.4 of ASCE 7. The uniform design live load in unoccupied landscaped areas on roofs shall be 20 psf (0.958 kN/m 2 ). The ...
Building Code 2018 of Maryland > 16 Structural Design > 1607 Live Loads > 1607.13 Roof Loads > 1607.13.3 Occupiable Roofs > 1607.13.3.1 Vegetative and Landscaped Roofs
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE