For every six or fraction of six accessible parking spaces, at least one shall be a van-accessible parking space.
Exception: In Group U private garages that serve Group R-2 and R-3 occupancies, van-accessible spaces shall be permitted to have vehicular routes, entrances, parking spaces and access aisles with a minimum vertical clearance of 7 feet (2134 mm).

Related Code Sections

1106.5 Accessibility, Van Spaces
For every six or fraction of six accessible parking spaces, at least one shall be a van-accessible parking space. Exception: In Group U private ...
1106.6 Accessibility, Van Spaces
For every six or fraction of six accessible parking spaces, at least one shall be a van-accessible parking space. Exception: In Group U private ...
502.2 General Site and Building Elements, Vehicle Space Size
Car parking spaces shall be 96 inches (2440 mm) minimum in width. Van parking spaces shall be 132 inches (3355 mm) minimum in width. Exception ...
502.7 General Site and Building Elements, Identification
703.6.3.1. Signs identifying van parking spaces shall contain the designation "van accessible." Signs shall be 60 inches (1525 mm) minimum above ...