11B-812.6.1 Van Accessible
JUMP TO FULL CODE CHAPTER
Vehicle spaces serving van accessible EVCS shall be 144 inches (3658 mm) wide minimum and shall have an adjacent access aisle complying with Section 11B-812.7.
Related Code Sections
11B-812.6.1 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Van Accessible
Vehicle spaces serving van accessible EVCS shall be 144 inches (3658 mm) wide minimum and shall have an adjacent access aisle complying with Section ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-812 Electric Vehicle Charging Stations > 11B-812.6 Vehicle Spaces > 11B-812.6.1 Van Accessible
1109A.8.6 Housing Accessibility, Van Accessible Parking Space
One in every eight accessible spaces, but not less than one, shall be van accessible and shall be constructed in accordance with the following ...
Los Angeles Building Code > 11A Housing Accessibility > 1109A Parking Facilities > 1109A.8 Design and Construction > 1109A.8.6 Van Accessible Parking Space
Figure 11A-2B Housing Accessibility, Single and Van Accessible Parking Stalls
Los Angeles Building Code > 11A Housing Accessibility > 11A-2B Single and Van Accessible Parking Stalls
11B-812.8.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Five to Twenty-Five
Where five to twenty-five total EVCS are provided, one van accessible EVCS shall be identified by an ISA complying with Section 11B -703.7.2.1. The ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-812 Electric Vehicle Charging Stations > 11B-812.8 Identification Signs > 11B-812.8.2 Five to Twenty-Five