• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1503.8.1 Valve Seals

California Plumbing Code 2016 > 15 Alternate Water Sources for Nonpotable Applications > 1503.0 Recycled Water Supply Systems in Buildings > 1503.8 Valves > 1503.8.1 Valve Seals
JUMP TO FULL CODE CHAPTER
The master reclaimed (recycled) water shut-off valve and/or the reclaimed (recycled) water meter curb cock and each valve within a wall shall be sealed after the recycled water supply system has been approved and placed into operation. These seals shall be either crimped lead wire seal or plastic break away seal which, if broken after system approval, shall be deemed conclusive evidence that the recycled water supply system has been accessed. The seals shall be purple, numbered, and contain the words "RECYCLED WATER", and shall be supplied by the recycled water purveyor, or by other arrangements acceptable to the Authority Having Jurisdiction.

Related Code Sections


1503.8.1 Alternate Water Sources for Nonpotable Applications, Valve Seals
The master reclaimed (recycled) water shut-off valve and/or the reclaimed (recycled) water meter curb cock and each valve within a wall shall ...
California Plumbing Code 2016 > 15 Alternate Water Sources for Nonpotable Applications > 1503.0 Recycled Water Supply Systems in Buildings > 1503.8 Valves > 1503.8.1 Valve Seals
1505.8.1 Alternate Water Sources for Nonpotable Applications, Valve Seals
The master reclaimed (recycled) water shut-off valve and/or the reclaimed (recycled) water meter curb cock and each valve within a wall shall ...
California Plumbing Code 2019 > 15 Alternate Water Sources for Nonpotable Applications > 1505.0 Recycled Water Supply Systems in Buildings > 1505.8 Valves > 1505.8.1 Valve Seals
5.508.2.2.2.2.1 Nonresidential Mandatory Measures, Chain Tethers
Chain tethers to fit over the stem are required for valves designed to have seal caps. Exception: Valves with seal caps that are not removed from ...
California Green Building Standards Code 2019 > 5 Nonresidential Mandatory Measures > 5.508 Outdoor Air Quality > 5.508.2 Supermarket Refrigerant Leak Reduction > 5.508.2.2 Valves > 5.508.2.2.2 Access Valves > 5.508.2.2.2.2 Seal Caps > 5.508.2.2.2.2.1 Chain Tethers
5.508.2.2.2.2.1 Nonresidential Mandatory Measures, Chain Tethers
Chain tethers to fit over the stem are required for valves designed to have seal caps. Exception: Valves with seal caps that are not removed from ...
California Green Building Standards Code 2016 > 5 Nonresidential Mandatory Measures > 5.508 Outdoor Air Quality > 5.508.2 Supermarket Refrigerant Leak Reduction > 5.508.2.2 Valves > 5.508.2.2.2 Access Valves > 5.508.2.2.2.2 Seal Caps > 5.508.2.2.2.2.1 Chain Tethers
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE