P2903.9.4 Valve Requirements
JUMP TO FULL CODE CHAPTER
Valves shall be compatible with the type of piping material installed in the system. Valves shall conform to one of the standards listed in Table P2903.9.4 or shall be approved. Valves intended to supply drinking water shall meet the requirements of NSF 61.
VALVES
MATERIAL | STANDARD |
Chlorinated polyvinyl chloride (CPVC) plastic | ASME A112.4.14, ASME A112.18.1/CSA B125.1, ASTM F1970, CSA B125.3 |
Copper or copper alloy | ASME A112.4.14, ASME A112.18.1/CSA B125.1, ASME B16.34, CSA B125.3, MSS SP-67, MSS SP-80, MSS SP-110 |
Gray and ductile iron | ASTM A126, AWWA C500, AWWA C504, AWWA C507, MSS SP-42, MSS SP-67, MSS SP-70, MSS SP-71, MSS SP-72, MSS SP-78 |
Cross-linked polyethylene (PEX) plastic | ASME A112.4.14, ASME A112.18.1/CSA B125.1, CSA B125.3, NSF 359 |
Polypropylene (PP) plastic | ASME A112.4.14, ASTM F2389 |
Polyvinyl chloride (PVC) plastic | ASME A112.4.14, ASTM F1970 |
Related Code Sections
712.2 Sanitary Drainage, Valves Required
required by Section 712.1 or, where the discharge pipe from the ejector is below grade, the valves shall be accessibly located outside the sump below ...
2014 FBC - Plumbing, 5th edition > 7 Sanitary Drainage > 712 Sumps and Ejectors > 712.2 Valves Required
712.2 Sanitary Drainage, Valves Required
required by Section 712.1 or, where the discharge pipe from the ejector is below grade, the valves shall be accessibly located outside the sump below ...
2017 FBC - Plumbing, 6th edition > 7 Sanitary Drainage > 712 Sumps and Ejectors > 712.2 Valves Required
712.2 Sanitary Drainage, Valves Required
required by Section 712.1 or, where the discharge pipe from the ejector is below grade, the valves shall be accessibly located outside the sump below ...
2020 FBC - Plumbing, 7th edition > 7 Sanitary Drainage > 712 Sumps and Ejectors > 712.2 Valves Required
P2903.9.4 Water Supply and Distribution, Valve Requirements
and plug valves intended to supply drinking water shall meet the requirements of NSF 61 ...
2014 FBC - Residential, 5th edition > 29 Water Supply and Distribution > P2903 Water-Supply System > P2903.9 Valves > P2903.9.4 Valve Requirements
P2903.9.4 Water Supply and Distribution, Valve Requirements
P2903.9.4 or shall be approved . Valves intended to supply drinking water shall meet the requirements of NSF 61. TABLE P2903.9.4 VALVES ...
2017 FBC - Residential, 6th edition > 29 Water Supply and Distribution > P2903 Water-Supply System > P2903.9 Valves > P2903.9.4 Valve Requirements