• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

709.4 Values for Indirect Waste Receptor

Plumbing Code 2018 of Kansas > 7 Sanitary Drainage > 709 Fixture Units > 709.4 Values for Indirect Waste Receptor
JUMP TO FULL CODE CHAPTER
The drainage fixture unit load of an indirect waste receptor receiving the discharge of indirectly connected fixtures shall be the sum of the drainage fixture unit values of the fixtures that discharge to the receptor, but not less than the drainage fixture unit value given for the indirect waste receptor in Table 709.1 or 709.2.

709.4.1 Clear-Water Waste Receptors

Where waste receptors such as floor drains, floor sinks and hub drains receive only clear-water waste from display cases, refrigerated display cases, ice bins, coolers and freezers, such receptors shall have a drainage fixture unit value of one-half.

Related Code Sections


709.4 Sanitary Drainage, Values for Indirect Waste Receptor
The drainage fixture unit load of an indirect waste receptor receiving the discharge of indirectly connected fixtures shall be the sum ...
Plumbing Code 2018 of Kansas > 7 Sanitary Drainage > 709 Fixture Units > 709.4 Values for Indirect Waste Receptor
802.4 Indirect/Special Waste, Waste Receptors
A waste receptor shall be sized for the maximum discharge of all indirect waste pipes served by the receptor ...
Plumbing Code 2018 of Kansas > 8 Indirect/Special Waste > 802 Indirect Wastes > 802.4 Waste Receptors
Section P2706 Plumbing Fixtures, Waste Receptors
of indirect waste piping. Exceptions: A kitchen sink trap is acceptable for use as a receptor for a dishwasher. A laundry tray is acceptable ...
Residential Code 2018 of Kansas > 27 Plumbing Fixtures > P2706 Waste Receptors
802.4.2 Indirect/Special Waste, Hub Drains
A hub drain shall be in the form of a hub or a pipe extending not less than 1 inch (25 mm) above a water-impervious floor ...
Plumbing Code 2018 of Kansas > 8 Indirect/Special Waste > 802 Indirect Wastes > 802.4 Waste Receptors > 802.4.2 Hub Drains
802.4.3 Indirect/Special Waste, Standpipes
As an alternative for a laundry tray fixture connecting directly to a drainage system, a laundry tray waste line without ...
Plumbing Code 2018 of Kansas > 8 Indirect/Special Waste > 802 Indirect Wastes > 802.4 Waste Receptors > 802.4.3 Standpipes
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING