• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

123-222 Uses Permitted With Restrictions

NYC Zoning Resolution > XII Special Purpose Districts > 3 - Special Mixed Use District (MX-1), (MX-2), (MX-4), (MX-5), (MX-6), (MX-7), (MX-8), (MX-9), (MX-10), (MX-11), (MX-12), (MX-13), (MX-14), (MX-15), (MX-16), (MX-17), (MX-18), (MX-20) > 123-20 Special Use Regulations > 123-22 Modification of Use Groups 16, 17 and 18 > 123-222 Uses Permitted With Restrictions
JUMP TO FULL CODE CHAPTER
The following uses from Use Groups 16 and 17 are permitted in Special Mixed Use Districts subject to the certification requirements and locational restrictions of this Section:
From Use Group 16A:
Animal hospitals or kennels
Blacksmith shops
Carpentry, custom woodworking or custom furniture making shops
Fuel, oil, or coal sales, open or enclosed, limited to 5,000 square feet of lot area per establishment
Mirror silvering shops
Sign painting shops, with no limitation on floor area per establishment
Silver plating shops, custom
Soldering or welding shops
Tool, die, or pattern-making establishments, or similar small machine shops
Trade schools for adults, that use substances in quantities required under the City Right-to-Know Law to file a Risk Management Plan for Extremely Hazardous Substances
From Use Group 16B:
Automobile, truck, motorcycle or trailer body repairs, provided such use is conducted within a completely enclosed building
From Use Group 16D:
Carpet cleaning establishments
Dry cleaning or cleaning and dyeing establishments, with no limitation on type of operation, solvents, floor area or capacity per establishment
Laundries, medical or laboratory
Linen or towel supply establishments, where cleaning is done on the same zoning lot
Packing or crating establishments for substances in quantities required under the City Right-to-Know Law to file a Risk Management Plan for Extremely Hazardous Substances
Photographic developing or printing, with no limitation on floor area per establishment
Warehouses for substances in quantities required under the City Right-to-Know Law to file a Risk Management Plan for Extremely Hazardous Substances
Wholesale establishments selling, as part of their stock, substances in quantities required under the City Right-to-Know Law to file a Risk Management Plan for Extremely Hazardous Substances, with no limitation on accessory storage
From Use Group 17B (Manufacturing Establishments):
Adhesives, excluding manufacture of basic components
Advertising displays
Aircraft, including parts
Automobiles, trucks or trailers, including parts or rebuilding of engines
Beverages, non-alcoholic
Boats less than 200 feet in length, building or repair, open or enclosed, provided that such use or portion thereof may be conducted outside a completely enclosed building only if located at a distance greater than 200 feet from a Residence District boundary, or if effectively screened by a wall or fence at least eight feet in height with no boat building located less than 30 feet from a Residence District boundary
Brushes or brooms
Cameras or other photographic equipment, except film
Canvas
Carpets
Ceramic products, including pottery, small glazed tile, or similar products
Chemicals, compounding or packaging
Cosmetics or toiletries
Cotton ginning, or cotton wadding or linters
Electrical appliances, including lighting fixtures, irons, fans, toasters, electric toys, or similar appliances
Electrical equipment assembly, including home radio or television receivers, home movie equipment, or similar products, but not including electrical machinery
Electrical supplies, including wire or cable assembly, switches, lamps, insulation, dry cell batteries, or similar supplies
Film, photographic
Food products, except slaughtering of meat or preparation of fish for packaging
Ice, dry
Ink or inked ribbon
Laboratories, research, experimental or testing
Leather products, including shoes, machine belting, or similar products
Luggage
Machines, business, including typewriters, accounting machines, calculators, card-counting equipment, or similar products
Machinery, miscellaneous, including washing machines, firearms, refrigerators, air-conditioning, commercial motion picture equipment, or similar products
Machine tools, including metal lathes, metal presses, metal stamping machines, woodworking machines, or similar products
Metal finishing, plating, grinding, sharpening, polishing, cleaning, rust-proofing, heat treatment, or similar products
Metal stamping or extrusion, including costume jewelry, pins and needles, razor blades, bottle caps, buttons, kitchen utensils, or similar products
Motorcycles, including parts
Musical instruments, including pianos or organs
Novelty products
Optical equipment, clocks or similar precision instruments
Orthopedic or medical appliances, including artificial limbs, braces, supports, stretchers, or similar appliances
Paper products, including envelopes, stationery, bags, boxes, shipping containers, bulk goods, tubes, wallpaper printing, or similar products
Perfumes or perfumed soaps, compounding only
Pharmaceutical products
Plastic products, including tableware, phonograph records, buttons, or similar products
Printing or publishing, with no limitation on floor area per establishment
Rubber products, such as washers, gloves, footwear, bathing caps, atomizers, or similar products, excluding manufacture of natural or synthetic rubber
Silverware, plate or sterling
Sporting or athletic equipment, including balls, baskets, cues, gloves, bats, racquets, rods, or similar products
Statuary, mannequins, figurines, or religious art goods, excluding foundry operations
Steel products, miscellaneous fabrication or assembly, including steel cabinets, doors, fencing, metal furniture, or similar products
Textiles, dyeing or printing
Tobacco, including curing, or tobacco products
Tools or hardware, including bolts, nuts, screws, doorknobs, drills, hand tools or cutlery, hinges, house hardware, locks, non-ferrous metal castings, plumbing appliances, or similar products
Toys
Umbrellas
Vehicles, children's, including bicycles, scooters, wagons, baby carriages, or similar vehicles
Venetian blinds, window shades, or awnings, with no limitation on production or on floor area per establishment
Wood products, including furniture, boxes, crates, baskets, pencils, cooperage works, or similar products
Uses accessory to the preceding listed uses
Any use from Use Group 16 or 17, listed in this Section, may only locate in a building enlarged or developed after December 10, 1997, containing a use listed in Section 123-21 (Modification of Use Groups 2, 3 and 4), or share a common wall with such building, upon certification by a licensed architect or engineer to the Department of Buildings that any such use listed in Use Group 16 or 17:
(a)        does not have a New York City or New York State environmental rating of "A", "B" or "C" under Section 24—153 of the New York City Administrative Code for any process equipment requiring a New York City Department of Environmental Protection operating certificate or New York State Department of Environmental Conservation state facility permit; and
(b)        is not required, under the City Right-to-Know Law, to file a Risk Management Plan for Extremely Hazardous Substances.

Related Code Sections


§28-401.16 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work, Restrictions on Use
No holder of a license issued under this chapter shall authorize, consent to or permit the use of his or her license by or on behalf of any other ...
NYC General Admin. Provisions 2022 > 4 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work > 401 General > §28-401.16 Restrictions on Use
11.2.3.1.4 Design Approaches, Restrictions
When either the density/area method or room design method is used, the following shall apply: *For areas of sprinkler operation less than 1500 ft ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 11 Design Approaches > 11.2 Occupancy Hazard Fire Control Approach for Spray Sprinklers > 11.2.3 Water Demand Requirements — Hydraulic Calculation Methods > 11.2.3.1 General > 11.2.3.1.4 Restrictions
8.3.4 Installation Requirements, Sprinklers With K-Factors Less Than K-5.6 (80)
with a nominal K-factor of K-5.6 (80) operating at 7 psi (0.5 bar), sprinklers having a smaller orifice shall be permitted, subject to the following restrictions ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 8 Installation Requirements > 8.3 Use of Sprinklers > 8.3.4 Sprinklers With K-Factors Less Than K-5.6 (80)
§28-105.12.1 Administration, Compliance With Code
Permits shall be deemed to incorporate the provisions that the applicant, the owner, their agents, employees, and contractors shall carry out ...
NYC General Admin. Provisions 2008 > 1 Administration > 105 Permits > §28-105.12 Conditions of Permit > §28-105.12.1 Compliance With Code
§28-105.12.1 Administration, Compliance With Code
Permits shall be deemed to incorporate the provisions that the applicant, the owner, their agents, employees, and contractors shall carry out ...
NYC General Admin. Provisions 2014 > 1 Administration > 105 Permits > §28-105.12 Conditions of Permit > §28-105.12.1 Compliance With Code
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING