Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

356.10 Uses Permitted

National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 356 Liquidtight Flexible Nonmetallic Conduit: Type LFNC > 356.10 Uses Permitted
JUMP TO FULL CODE CHAPTER
LFNC shall be permitted to be used in exposed or concealed locations for the following purposes:
  1. Where flexibility is required for installation, operation, or maintenance.
  2. Where protection of the contained conductors is required from vapors, machine oils, liquids, or solids.
  3. For outdoor locations where listed and marked as suitable for the purpose.
  4. For direct burial where listed and marked for the purpose.
  5. Type LFNC shall be permitted to be installed in lengths longer than 1.8 m (6 ft) where secured in accordance with 356.30.
  6. Type LFNC-B as a listed manufactured prewired assembly, metric designator 16 through 27 (trade size 1/2 through 1) conduit.
  7. For encasement in concrete where listed for direct burial and installed in compliance with 356.42.
  8. Conductors or cables rated at a temperature higher than the listed temperature rating of LFNC conduit shall be permitted to be installed in LFNC, provided the conductors or cables are not operated at a temperature higher than the listed temperature rating of the LFNC.
Informational Note: Extreme cold can cause some types of nonmetallic conduits to become brittle and therefore more susceptible to damage from physical contact.

Related Code Sections


310.10 Wiring Methods and Materials, Uses Permitted
The conductors described in 310.4 shall be permitted for use in any of the wiring methods covered in Chapter 3 and as specified in their respective ...
National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 310 Conductors for General Wiring > 310.10 Uses Permitted
311.32 Wiring Methods and Materials, Uses Permitted
Type MV cable shall be permitted for use on power systems rated up to and including 35,000 volts, nominal, as follows: In wet or dry locations ...
National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 311 Medium Voltage Conductors and Cable > 311.32 Uses Permitted
320.10 Wiring Methods and Materials, Uses Permitted
block or tile walls where such walls are not exposed or subject to excessive moisture or dampness Informational Note: The "Uses Permitted ...
National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 320 Armored Cable: Type AC > 320.10 Uses Permitted
322.10 Wiring Methods and Materials, Uses Permitted
Flat cable assemblies shall be permitted only as follows: As branch circuits to supply suitable tap devices for lighting, small appliances ...
National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 322 Flat Cable Assemblies: Type FC > 322.10 Uses Permitted
324.10 Wiring Methods and Materials, Uses Permitted
Use of FCC systems shall be permitted both for general-purpose and appliance branch circuits and for individual branch circuits ...
National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 324 Flat Conductor Cable: Type FCC > 324.10 Uses Permitted
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING