• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

62-24 Uses on Piers and Platforms

NYC Zoning Resolution > VI Special Regulations Applicable to Certain Areas > 2 - Special Regulations Applying in the Waterfront Area > 62-20 Special Use Regulations > 62-24 Uses on Piers and Platforms
JUMP TO FULL CODE CHAPTER
Uses on existing piers or existing platforms shall be subject to the provisions of Section 62-241. Uses on new piers or new platforms shall be subject to the provisions of Section 62-242.

62-241 Uses on Existing Piers and Platforms

The use of an existing platform may be continued or such use may be changed, enlarged or extended in accordance with the use regulations of the applicable district.
The use of an existing pier may be continued or such use may be changed, enlarged or extended in accordance with the use regulations of the applicable district provided that any use within a building or other structure on the pier meets one of the following requirements:
(a)        such use is a WD use; or
(b)        the building or other structure within which such use is located existed on October 25, 1993; or
(c)        the building or other structure within which such use is located complies with the height and setback regulations of Section 62-342 (Developments on piers).
In addition, the following use regulations shall apply on piers:
(d)        the following uses, not otherwise limited in size by their Use Group listing, shall be limited to 20,000 square feet of floor area per establishment:
(1)        all uses in Use Groups 6A and 6C;
(2)        the following uses in Use Group 9A;
(i)        clothing or costume rental establishments;
(ii)        typewriter or other small business machine sales, rental or repairs;
(3)        all uses in Use Group 10 with parking categories "B" or "B1";
(4)        the preceding uses, when listed in other Use Groups;
(5)        wholesale establishments or warehouses that provide accessory retail sales areas; and
(e)        no residential use shall be permitted within a building on a pier unless 50 percent or more of the floor area of the story at the level of public access is allocated for occupancy by WE uses, subject to the size limitations set forth in paragraph (d) of this Section.
Any use on an existing pier not permitted by the foregoing provisions of this Section shall only be allowed by special permit of the City Planning Commission pursuant to Section 62-835 (Developments on piers or platforms).

62-242 Uses on New Piers and Platforms

New piers and new platforms shall be limited to WD uses or to the following WE uses: playgrounds or publicly accessible private parks. Changes of use to any other WE use are permitted only by special permit, pursuant to Section 62-835 (Developments on piers or platforms).

Related Code Sections


1105.1 Recreational Facilities, Accessible Routes
: Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in Section 1103.2.1. Where the total ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 11 Recreational Facilities > 1105 Fishing Piers and Platforms > 1105.1 Accessible Routes
1110.4.11 Accessibility, Fishing Piers and Platforms
Fishing piers and platforms shall be accessible and be located on an accessible route and shall be in compliance with Section 1105 (Fishing Piers ...
NYC Building Code 2022 > 11 Accessibility > 1110 Recreational Facilities > 1110.4 Recreational Facilities > 1110.4.11 Fishing Piers and Platforms
1109.8 Accessibility, Lifts
serving areas of sport activity. An accessible route instead of gangways serving recreational boating facilities and fishing piers and platforms ...
NYC Building Code 2022 > 11 Accessibility > 1109 Other Features and Facilities > 1109.8 Lifts
1013.1 Means of Egress, Where Required
for the following locations: On the loading side of loading docks or piers. On the audience side of stages and raised platforms, including steps leading up ...
NYC Building Code 2014 > 10 Means of Egress > 1013 Guards > 1013.1 Where Required
1015.2 Means of Egress, Where Required
: On the loading side of loading docks or piers. On the audience side of stages and raised platforms, including stairs and ramps leading up ...
NYC Building Code 2022 > 10 Means of Egress > 1015 Guards > 1015.2 Where Required
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING