5.4.4.3.1
Glass or plastics, where used in elevator cars, shall conform to the following:
(a) Glass shall meet the requirements of 2.14.1.8.
(b) Plastics shall meet the requirements of ANSI Z97.1; 16 CFR Part 1201; or CAN/CGSB-12.1, CAN/CGSB-12.11, and CAN/CGSB-12.12, whichever is applicable.
5.4.4.3.2
Glass or plastics shall be secured as required by 5.4.4.1.2.
5.4.4.3.3 Weatherproof Material
Materials shall be of a weatherproof type.