1910.109(e) Use of Explosives and Blasting Agents
JUMP TO FULL CODE CHAPTER
While explosives are being handled or used, smoking shall not be permitted and no one near the explosives shall possess matches, open light or other fire or flame. No person shall be allowed to handle explosives while under the influence of intoxicating liquors, narcotics, or other dangerous drugs.
When blasting is done in congested areas or in close proximity to a structure, or any other installation that may be damaged, the blast shall be covered before firing with a mat constructed so that it is capable of preventing fragments from being thrown.
Persons authorized to prepare explosive charges or conduct blasting operations shall use every reasonable precaution, including but not limited to warning signals, flags, barricades, or woven wire mats to insure the safety of the general public and workmen.
Blasting operations shall be conducted during daylight hours.
Whenever blasting is being conducted in the vicinity of gas, electric, water, fire alarm, telephone, telegraph, and steam utilities, the blaster shall notify the appropriate representatives of such utilities at least 24 hours in advance of blasting, specifying the location and intended time of such blasting. Verbal notice shall be confirmed with written notice.
Due precautions shall be taken to prevent accidental discharge of electric blasting caps from current induced by radar, radio transmitters, lightning, adjacent powerlines, dust storms, or other sources of extraneous electricity. These precautions shall include:
The suspension of all blasting operations and removal of persons from the blasting area during the approach and progress of an electric storm.
The posting of signs warning against the use of mobile radio transmitters on all roads within 350 feet of the blasting operations.
Original containers or Class II magazines shall be used for taking detonators and other explosives from storage magazines to the blasting area.
Empty containers and paper and fiber packing materials which have previously contained explosive materials shall be disposed of in a safe manner, or reused in accordance with the Department of Transportation's Hazardous Materials Regulations (49 CFR parts 177-180).
Explosives or blasting equipment that are obviously deteriorated or damaged shall not be used.
No explosives shall be abandoned.
Containers of explosives shall not be opened in any magazine or within 50 feet of any magazine. In opening kegs or wooden cases, no sparking metal tools shall be used; wooden wedges and either wood, fiber or rubber mallets shall be used. Nonsparking metallic slitters may be used for opening fiberboard cases.
All drill holes shall be sufficiently large to admit freely the insertion of the cartridges of explosives.
When loading blasting agents pneumatically over electric blasting caps, semiconductive delivery hose shall be used and the equipment shall be bonded and grounded.
No holes shall be loaded except those to be fired in the next round of blasting. After loading, all remaining explosives shall be immediately returned to an authorized magazine.
Drilling shall not be started until all remaining butts of old holes are examined with a wooden stick for unexploded charges, and if any are found, they shall be refired before work proceeds.
No person shall be allowed to deepen drill holes which have contained explosives.
After loading for a blast is completed, all excess blasting caps or electric blasting caps and other explosives shall immediately be returned to their separate storage magazines.
Tamping shall be done only with wood rods without exposed metal parts, but nonsparking metal connectors may be used for jointed poles. Violent tamping shall be avoided. Primed cartridges shall not be tamped.
Primers shall be made up only as required for each round of blasting.
No blasting cap shall be inserted in the explosives without first making a hole in the cartridge for the cap with a wooden punch of proper size or standard cap crimper.
Explosives shall not be extracted from a hole that has once been charged or has misfired unless it is impossible to detonate the unexploded charge by insertion of a fresh additional primer.
If there are any misfires while using cap and fuse, all persons shall be required to remain away from the charge for at least 1 hour. If electric blasting caps are used and a misfire occurs, this waiting period may be reduced to 30 minutes. Misfires shall be handled under the direction of the person in charge of the blasting and all wires shall be carefully traced and search made for unexploded charges.
Blasters, when testing circuits to charged holes, shall use only blasting galvanometers designed for this purpose.
Only the employee making leading wire connections in electrical firing shall be allowed to fire the shot. Leading wires shall remain shorted and not be connected to the blasting machine or other source of current until the charge is to be fired.
When fuse is used, the blasting cap shall be securely attached to the safety fuse with a standard-ring type cap crimper. All primers shall be assembled at least 50 feet from any magazine.
Before a blast is fired, the employer shall require that a loud warning signal be given by the person in charge, who has made certain that all surplus explosives are in a safe place, all persons and vehicles are at a safe distance or under sufficient cover, and that an adequate warning has been given.
Related Code Sections
1910.109(e) Hazardous Materials, Use of Explosives and Blasting Agents
Persons authorized to prepare explosive charges or conduct blasting operations shall use every reasonable precaution, including but not limited ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.109 Explosives and Blasting Agents > 1910.109(e) Use of Explosives and Blasting Agents
1910.109(e)(1)(ii) Hazardous Materials,
Original containers or Class II magazines shall be used for taking detonators and other explosives from storage magazines to the blasting area ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.109 Explosives and Blasting Agents > 1910.109(e) Use of Explosives and Blasting Agents > 1910.109(e)(1) General Provisions > 1910.109(e)(1)(ii)
1910.109(e)(1)(vii)(b) Hazardous Materials,
The posting of signs warning against the use of mobile radio transmitters on all roads within 350 feet of the blasting operations ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.109 Explosives and Blasting Agents > 1910.109(e) Use of Explosives and Blasting Agents > 1910.109(e)(1) General Provisions > 1910.109(e)(1)(vii) > 1910.109(e)(1)(vii)(b)
1910.109(e)(1)(iv) Hazardous Materials,
Persons authorized to prepare explosive charges or conduct blasting operations shall use every reasonable precaution, including but not limited ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.109 Explosives and Blasting Agents > 1910.109(e) Use of Explosives and Blasting Agents > 1910.109(e)(1) General Provisions > 1910.109(e)(1)(iv)
1910.109(e)(1)(i) Hazardous Materials,
While explosives are being handled or used, smoking shall not be permitted and no one near the explosives shall possess matches, open light or other ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.109 Explosives and Blasting Agents > 1910.109(e) Use of Explosives and Blasting Agents > 1910.109(e)(1) General Provisions > 1910.109(e)(1)(i)