L 411.3 Use of Alternate Water Sources for Landscape Irrigation
Go To Full Code Chapter
Where available by pre-existing treatment, storage, or distribution network, and where approved by the Authority Having Jurisdiction, alternative water source(s) shall be utilized for landscape irrigation. Where adequate capacity and volumes of pre-existing alternative water sources are available, the irrigation system shall be designed to use a minimum of 75 percent of alternative water for the annual irrigation demand before supplemental potable water is used.
Related Code Sections
L 411.3 Sustainable Practices, Use of Alternate Water Sources for Landscape Irrigation
water source(s) shall be utilized for landscape irrigation. Where adequate capacity and volumes of pre-existing alternative water sources are available ...
Section P3009 Sanitary Drainage, Subsurface Landscape Irrigation Systems
nonpotable reuse water used for subsurface landscape irrigation systems shall not be required to be dyed ...
1504.0 Alternate Water Sources for Nonpotable Applications, Subsurface Irrigation System Zones
Irrigation or disposal fields shall be permitted to have one or more valved zones. Each zone shall be of a size to receive the gray water anticipated ...
1504.7 Alternate Water Sources for Nonpotable Applications, Subsoil Irrigation Field
Subsoil irrigation fields shall comply with Section 1504.7.1 through Section 1504.7.3 ...
L 411.7 Sustainable Practices, System Performance Requirements
The landscape irrigation system shall be designed and installed to:
Prevent irrigation water from runoff out of the irrigation zone.
Prevent ...