• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section G2445 (621) Unvented Room Heaters

Residential Code 2018 of Kansas > 24 Fuel Gas > G2445 (621) Unvented Room Heaters
JUMP TO FULL CODE CHAPTER

G2445.1 (621.1) General

Unvented room heaters shall be tested in accordance with ANSI Z21.11.2 and shall be installed in accordance with the conditions of the listing and the manufacturer's instructions.

G2445.2 (621.2) Prohibited Use

One or more unvented room heaters shall not be used as the sole source of comfort heating in a dwelling unit.

G2445.3 (621.3) Input Rating

Unvented room heaters shall not have an input rating in excess of 40,000 Btu/h (11.7 kW).

G2445.4 (621.4) Prohibited Locations

The location of unvented room heaters shall comply with Section G2406.2.

G2445.5 (621.5) Room or Space Volume

The aggregate input rating of all unvented appliances installed in a room or space shall not exceed 20 Btu/h per cubic foot (207 W/m3) of volume of such room or space. Where the room or space in which the appliances are installed is directly connected to another room or space by a doorway, archway or other opening of comparable size that cannot be closed, the volume of such adjacent room or space shall be permitted to be included in the calculations.

G2445.6 (621.6) Oxygen-Depletion Safety System

Unvented room heaters shall be equipped with an oxygen-depletion-sensitive safety shutoff system. The system shall shut off the gas supply to the main and pilot burners when the oxygen in the surrounding atmosphere is depleted to the percent concentration specified by the manufacturer, but not lower than 18 percent. The system shall not incorporate field adjustment means capable of changing the set point at which the system acts to shut off the gas supply to the room heater.

G2445.7 (621.7) Unvented Decorative Room Heaters

An unvented decorative room heater shall not be installed in a factory-built fireplace unless the fireplace system has been specifically tested, listed and labeled for such use in accordance with UL 127.

G2445.7.1 (621.7.1) Ventless Firebox Enclosures

Ventless firebox enclosures used with unvented decorative room heaters shall be listed as complying with ANSI Z21.91.

Related Code Sections


Section G2445 Fuel Gas, (621) Unvented Room Heaters
Unvented room heaters shall be tested in accordance with ANSI Z21.11.2 and shall be installed in accordance with the conditions of the listing ...
Residential Code 2018 of Kansas > 24 Fuel Gas > G2445 (621) Unvented Room Heaters
G2445.4 Fuel Gas, (621.4) Prohibited Locations
The location of unvented room heaters shall comply with Section G2406.2 ...
Residential Code 2018 of Kansas > 24 Fuel Gas > G2445 (621) Unvented Room Heaters > G2445.4 (621.4) Prohibited Locations
G2445.6 Fuel Gas, (621.6) Oxygen-Depletion Safety System
Unvented room heaters shall be equipped with an oxygen-depletion-sensitive safety shutoff system. The system shall shut off the gas supply ...
Residential Code 2018 of Kansas > 24 Fuel Gas > G2445 (621) Unvented Room Heaters > G2445.6 (621.6) Oxygen-Depletion Safety System
G2445.7.1 Fuel Gas, (621.7.1) Ventless Firebox Enclosures
Ventless firebox enclosures used with unvented decorative room heaters shall be listed as complying with ANSI Z21.91 ...
Residential Code 2018 of Kansas > 24 Fuel Gas > G2445 (621) Unvented Room Heaters > G2445.7 (621.7) Unvented Decorative Room Heaters > G2445.7.1 (621.7.1) Ventless Firebox Enclosures
Section 621 Specific Appliances, (IFGC) Unvented Room Heaters
Unvented room heaters shall be tested in accordance with ANSI Z21.11.2 and shall be installed in accordance with the conditions of the listing ...
Fuel Gas Code 2018 of Kansas > 6 Specific Appliances > 621 (IFGC) Unvented Room Heaters
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE