Containers of explosives, except fiberboard containers, and packages of damaged or deteriorated explosives shall not be unpacked or repacked inside or within 50 feet (15 240 mm) of a magazine or in close proximity to other explosives.
5604.7.5.1 Storage of Opened Packages
Packages of explosives that have been opened shall be closed before being placed in a magazine.
5604.7.5.2 Nonsparking Tools
Tools used for the opening and closing of packages of explosives, other than metal slitters for opening paper, plastic or fiberboard containers, shall be made of nonsparking materials.
5604.7.5.3 Disposal of Packaging
Empty containers and paper and fiber packaging materials that previously contained explosives shall be disposed of or reused in an approved manner.
Upcodes Diagrams

Related Code Sections

502.9.4 Exhaust Systems, Explosives
, assembly or testing of explosives. Only nonferrous fan blades shall be used for fans located within the ductwork and through which hazardous materials ...
502.9.4 Exhaust Systems, Explosives
, assembly or testing of explosives. Only nonferrous fan blades shall be used for fans located within the ductwork and through which hazardous materials ...
502.9.4 Exhaust Systems, Explosives
, assembly or testing of explosives. Only nonferrous fan blades shall be used for fans located within the ductwork and through which hazardous materials ...
1210.3.2 Hydronic Piping, Work Approval
to the repacking of a slip or ball joint; however, records of such repacking shall be kept in the inspection records as provided in Section 1210.3.1, Item 3 ...
1210.3.2 Hydronic Piping, Work Approval
to the repacking of a slip or ball joint; however, records of such repacking shall be kept in the inspection records as provided in Section 1210.3.1, Item 3 ...