2405.5 Unit Skylights
JUMP TO FULL CODE CHAPTER
Unit skylights shall be tested and labeled as complying with AAMA/WDMA/CSA 101/I.S.2/A440 Voluntary Performance Specification for Windows, Skylights and Glass. The label shall state the name of the manufacturer, the approved agency, the product designation and the performance grade rating as specified in AAMA/WDMA/CSA 101/I.S.2/A440. If the product manufacturer has chosen to have the performance grade of the skylight rated separately for positive and negative design pressure, then the label shall state both performance grade ratings as specified in AAMA/WDMA/CSA 101/I.S.2/A440 and the skylight shall comply with Section 2405.5.2. If the skylight is not rated separately for positive and negative pressure, then the performance grade rating shown on the label shall be the performance grade rating determined in accordance with AAMA/WDMA/CSA 101/I.S.2/A440 for both positive and negative design pressure, and the skylight shall conform to Section 2405.5.1.
The design of unit skylights shall be based on the following equation:
where:
where:
Fg | = | Maximum load on the skylight determined from Equations 24-2 through 24-4 in Section 2404.2. |
PG | = | Performance grade rating of the skylight. |
The design of unit skylights rated for performance grade for both positive and negative design pressures shall be based on the following equations:
where:
Fgi and Fgo are determined in accordance with the following:
For Wo < D,
where:
For Wo < D,
where:
where:
PGPos | = | Performance grade rating of the skylight under positive design pressure, |
PGNeg | = | Performance grade rating of the skylight under negative design pressure, and |
Fgi and Fgo are determined in accordance with the following:
For Wo < D,
where:
Wo | = | Outward wind force, psf (kN/m2) as calculated in Section 1609. |
D | = | The dead weight of the glazing, psf (kN/m2) as determined in Section 2404.2 for glass, or by the weight of the plastic, psf (kN/m2) for plastic glazing. |
Fgi | = | Maximum load on the skylight determined from Equations 24-3 and 24-4 in Section 2404.2. |
Fgo | = | Maximum load on the skylight determined from Equation 24-2. |
For Wo < D,
where:
Wo | = | Outward wind force, psf (kN/m2) as calculated in Section 1609. |
D | = | The dead weight of the glazing, psf (kN/m2) as determined in Section 2404.2 for glass, or by the weight of the plastic for plastic glazing. |
Fgi | = | Maximum load on the skylight determined from Equations 24-2 through 24-4 in Section 2404.2. |
Fgo | = | 0. |
Related Code Sections
2405.5 Glass and Glazing, Unit Skylights
Unit skylights shall be tested and labeled as complying with 101/I.S.2/NAFS Voluntary Performance Specification for Windows, Skylights and Glass ...
NYC Building Code 2008 > 24 Glass and Glazing > 2405 Sloped Glazing and Skylights > 2405.5 Unit Skylights
2405.5 Glass and Glazing, Unit Skylights
Unit skylights shall be tested and labeled as complying with AAMA/WDMA/CSA 101/I.S.2/A440 Voluntary Performance Specification for Windows, Skylights ...
NYC Building Code 2014 > 24 Glass and Glazing > 2405 Sloped Glazing and Skylights > 2405.5 Unit Skylights
2610.1 Plastic, Light-Transmitting Plastic Glazing of Skylight Assemblies
Skylight assemblies glazed with light-transmitting plastic shall conform to the provisions of this section and Section 2606. Unit skylights glazed ...
NYC Building Code 2008 > 26 Plastic > 2610 Light-Transmitting Plastic Skylight Glazing > 2610.1 Light-Transmitting Plastic Glazing of Skylight Assemblies
2610.1 Plastic, Light-Transmitting Plastic Glazing of Skylight Assemblies
Skylight assemblies glazed with light-transmitting plastic shall conform to the provisions of this section and Section 2606. Unit skylights glazed ...
NYC Building Code 2014 > 26 Plastic > 2610 Light-Transmitting Plastic Skylight Glazing > 2610.1 Light-Transmitting Plastic Glazing of Skylight Assemblies
2405.4 Glass and Glazing, Framing
of 14 degrees (three units vertical in 12 units horizontal) in Group R-3 occupancies. All unit skylights installed in a roof with a pitch flatter than ...