• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Article 12 Unit Heaters

NYC 1968 Code (Vol I) > 14 Heating and Combustion Equipment > 12 Unit Heaters
JUMP TO FULL CODE CHAPTER

§27-813 General Requirements

All gas or oil burning unit heaters shall conform to the requirements of article five of this subchapter.

§27-814 Supports

All suspended type direct-fired unit heaters shall be adequately supported by metal hangers, brackets, or other noncombustible supports with the clearances required in reference standard RS 14-15.

§27-815 Recessed Heaters

Recessed heaters shall be of an approved type, and shall be installed only in accordance with the conditions of approval.

§27-816 Fireplace Heaters

Gas-fired heaters, approved for use in fireplace recesses only, shall not be used elsewhere.

Related Code Sections


Article 12 Heating and Combustion Equipment, Unit Heaters
All gas or oil burning unit heaters shall conform to the requirements of article five of this subchapter ...
NYC 1968 Code (Vol I) > 14 Heating and Combustion Equipment > 12 Unit Heaters
Section 620 Specific Appliances, Unit Heaters
Unit heaters shall be tested in accordance with ANSI Z83.8 and shall be installed in accordance with the manufacturer's installation instructions ...
NYC Fuel Gas Code 2014 > 6 Specific Appliances > 620 Unit Heaters
Section 620 Specific Appliances, Unit Heaters
Unit heaters shall be tested in accordance with ANSI Z83.8 and shall be installed in accordance with the manufacturer's installation instructions ...
NYC Fuel Gas Code 2008 > 6 Specific Appliances > 620 Unit Heaters
Section 620 Specific Appliances, Unit Heaters
Unit heaters shall be tested in accordance with ANSI Z83.8/CSA 2.6 and shall be installed in accordance with the manufacturer's instructions ...
NYC Fuel Gas Code 2022 > 6 Specific Appliances > 620 Unit Heaters
Section 920 Specific Appliances, Fireplaces, Solid Fuel-Burning Equipment, and Noise Control Requirements, Unit Heaters
Unit heaters shall be installed in accordance with the listing and the manufacturer's installation instructions. Oil-fired unit heaters shall ...
NYC Mechanical Code 2014 > 9 Specific Appliances, Fireplaces, Solid Fuel-Burning Equipment, and Noise Control Requirements > 920 Unit Heaters
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING