• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms

2010 ADA Standards > 2 Scoping Requirements > 213 Toilet Facilities and Bathing Facilities > 213.2 Toilet Rooms and Bathing Rooms > 213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
JUMP TO FULL CODE CHAPTER
Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal.  Unisex bathing rooms shall contain one shower or one shower and one bathtub, one lavatory, and one water closet.  Doors to unisex toilet rooms and unisex bathing rooms shall have privacy latches.

Related Code Sections


213.2.1 Scoping Requirements, Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
bathing rooms shall contain one shower or one shower and one bathtub, one lavatory, and one water closet.  Doors to unisex toilet rooms ...
2010 ADA Standards > 2 Scoping Requirements > 213 Toilet Facilities and Bathing Facilities > 213.2 Toilet Rooms and Bathing Rooms > 213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
603 Plumbing Elements and Facilities, Toilet and Bathing Rooms
be permitted to swing into the required turning space. EXCEPTIONS : Doors to a toilet room or bathing room for a single occupant accessed ...
2010 ADA Standards > 6 Plumbing Elements and Facilities > 603 Toilet and Bathing Rooms
216.8 Scoping Requirements, Toilet Rooms and Bathing Rooms
or bathing facilities are permitted to use exceptions to 213.2, toilet rooms or bathing facilities complying with 603 shall be identified ...
2010 ADA Standards > 2 Scoping Requirements > 216 Signs > 216.8 Toilet Rooms and Bathing Rooms
222.1 Scoping Requirements, General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster ...
2010 ADA Standards > 2 Scoping Requirements > 222 Dressing, Fitting, and Locker Rooms > 222.1 General
805.4 Special Rooms, Spaces, and Elements, Toilet and Bathing Rooms
Toilet and bathing rooms that are provided as part of a patient or resident sleeping room shall comply with 603.  Where provided, no fewer than ...
2010 ADA Standards > 8 Special Rooms, Spaces, and Elements > 805 Medical Care and Long-Term Care Facilities > 805.4 Toilet and Bathing Rooms
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE