// CODE SNIPPET
1127A.7.2.3 Unisex Sanitary Facilities
JUMP TO FULL CODE CHAPTER
Unisex sanitary facilities shall be identified by a circle, 1/4 inch (6.4 mm) thick and 12 inches (305 mm) in diameter with a 1/4 inch (6.4 mm) thick triangle superimposed on the circle and within the 12-inch (305 mm) diameter. The triangle symbol shall contrast with the circle symbol, either light on a dark background or dark on a light background. The circle symbol shall contrast with the door, either light on a dark background or dark on a light background.
Related Code Sections
1127A.7.2.3 Housing Accessibility, Unisex Sanitary Facilities
Unisex sanitary facilities shall be identified by a circle, 1 / 4 inch (6.4 mm) thick and 12 inches (305 mm) in diameter with a 1 / 4 inch (6.4 ...
Los Angeles Building Code > 11A Housing Accessibility > 1127A Common Use Facilities > 1127A.7 Signs > 1127A.7.2 Identification Symbols > 1127A.7.2.3 Unisex Sanitary Facilities
11B-703.7.2.6.3 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Unisex Toilet and Bathing Facilities
A combined circle and triangle symbol shall be
located at entrances to unisex toilet and bathing
facilities. The combined circle and triangle symbol ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-703 Signs > 11B-703.7 Symbols of Accessibility > 11B-703.7.2 Symbols > 11B-703.7.2.6 Toilet and Bathing Facilities Geometric Symbols > 11B-703.7.2.6.3 Unisex Toilet and Bathing Facilities
11B-213 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Toilet Facilities and Bathing Facilities
Where toilet facilities and bathing facilities are provided, they shall comply with Section 11B -213. Where toilet facilities and bathing facilities ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-213 Toilet Facilities and Bathing Facilities