• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E3603.2 Ungrounded Service Conductors for Accessory Buildings and Structures

2014 FBC - Residential, 5th edition > 36 Services > E3603 Service, Feeder and Grounding Electrode Conductor Sizing > E3603.2 Ungrounded Service Conductors for Accessory Buildings and Structures
JUMP TO FULL CODE CHAPTER

Ungrounded conductors for other than dwelling units shall have an ampacity of not less than 60 amperes and shall be sized as required for feeders in Chapter 37.

Exceptions:
  1. For limited loads of a single branch circuit, the service conductors shall have an ampacity of not less than 15 amperes.
  2. For loads consisting of not more than two two-wire branch circuits, the service conductors shall have an ampacity of not less than 30 amperes.

Related Code Sections


E3603.2 Services, Ungrounded Service Conductors for Accessory Buildings and Structures
Ungrounded conductors for other than dwelling units shall have an ampacity of not less than 60 amperes and shall be sized as required for feeders ...
2014 FBC - Residential, 5th edition > 36 Services > E3603 Service, Feeder and Grounding Electrode Conductor Sizing > E3603.2 Ungrounded Service Conductors for Accessory Buildings and Structures
E3603.2 Services, Ungrounded Service Conductors for Accessory Buildings and Structures
Ungrounded conductors for other than dwelling units shall have an ampacity of not less than 60 amperes and shall be sized as required for feeders ...
2017 FBC - Residential, 6th edition > 36 Services > E3603 Service, Feeder and Grounding Electrode Conductor Sizing > E3603.2 Ungrounded Service Conductors for Accessory Buildings and Structures
E3602.1 Services, Ampacity of Ungrounded Conductors
Ungrounded service conductors shall have an ampacity of not less than the load served. For one-family dwellings, the ampacity of the ungrounded ...
2017 FBC - Residential, 6th edition > 36 Services > E3602 Service Size and Rating > E3602.1 Ampacity of Ungrounded Conductors
E3602.1 Services, Ampacity of Ungrounded Conductors
Ungrounded service conductors shall have an ampacity of not less than the load served. For one-family dwellings, the ampacity of the ungrounded ...
2014 FBC - Residential, 5th edition > 36 Services > E3602 Service Size and Rating > E3602.1 Ampacity of Ungrounded Conductors
E3407.3 General Requirements, Ungrounded Conductors
Insulation on the ungrounded conductors shall be a continuous color other than white, gray and green. [310.110(C)] Exception: An insulated ...
2017 FBC - Residential, 6th edition > 34 General Requirements > E3407 Conductor and Terminal Identification > E3407.3 Ungrounded Conductors
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE