// CODE SNIPPET
E3902.5 Unfinished Basement Receptacles
Go To Full Code Chapter
125-volt, single-phase, 15- and 20-ampere receptacles installed in unfinished basements shall have ground-fault circuit-interrupter protection for personnel. For purposes of this section, unfinished basements are defined as portions or areas of the basement not intended as habitable rooms. [210.8(A)(5)]
Exception: A receptacle supplying only a permanently installed fire alarm or burglar alarm system. Receptacles installed in accordance with this exception shall not be considered as meeting the requirement of Section E3901.9. [210.8(A)(5) Exception]
Related Code Sections
E3902.5 Power and Lighting Distribution, Unfinished Basement Receptacles
125-volt, single-phase, 15- and 20-ampere receptacles installed in unfinished basements shall have ground-fault circuit-interrupter protection ...
(B) Special Conditions, Branch Circuit
-interrupters. Informational Note: See 210.8(A)(5), Exception, for receptacles in dwelling-unit unfinished basements that supply power for fire alarm ...
E3901.9 Power and Lighting Distribution, Basements, Garages and Accessory Buildings
Not less than one receptacle outlet, in addition to any provided for specific equipment, shall be installed in each separate unfinished portion ...
(G) Wiring and Protection, Basements, Garages, and Accessory Buildings
In each separate unfinished portion of a basement ...
Section E3902 Power and Lighting Distribution, Ground-Fault and Arc-Fault Circuit-Interrupter Protection
)] 125-volt, single-phase, 15- and 20-ampere receptacles installed in unfinished basements shall have ground-fault circuit-interrupter ...