• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R337.7.9 Underside of Appendages

Los Angeles Residential Code > 3 Building Planning > R337.7 Exterior Covering > R337.7.9 Underside of Appendages
JUMP TO FULL CODE CHAPTER

When required by the enforcing agency the underside of overhanging appendages shall be enclosed to grade in accordance with the requirements of this chapter or the underside of the exposed underfloor shall consist of one of the following:

  1. Noncombustible material.
  2. Ignition-resistant material.
  3. One layer of 5/8-inch Type X gypsum sheathing applied behind an exterior covering on the underside of the floor projection.
  4. The exterior portion of a 1-hour fire resistive exterior wall assembly applied to the underside of the floor including assemblies using the gypsum panel and sheathing products listed in the Gypsum Association Fire Resistance Design Manual.
  5. The underside of a floor assembly that meets the performance criteria in accordance with the test procedures set forth in either of the following:

    1. 5.1. SFM Standard 12-7A-3; or
    2. 5.2. ASTM E2957

Exception: Heavy-timber structural columns and beams do not require protection.

Related Code Sections


707A.9 [SFM] Materials and Construction Methods for Exterior Wildfire Exposure, Underside of Appendages
When required by the enforcing agency the underside of overhanging appendages shall be enclosed to grade in accordance with the requirements ...
Los Angeles Building Code > 7A [SFM] Materials and Construction Methods for Exterior Wildfire Exposure > 707A Exterior Covering > 707A.9 Underside of Appendages
R337.7.9 Building Planning, Underside of Appendages
When required by the enforcing agency the underside of overhanging appendages shall be enclosed to grade in accordance with the requirements ...
Los Angeles Residential Code > 3 Building Planning > R337.7 Exterior Covering > R337.7.9 Underside of Appendages
1227.12.6.3 Interior Environment, Appendages and Equipment
Rooms shall be free of appendages and equipment which could facilitate suicide or self-mutilation ...
Los Angeles Building Code > 12 Interior Environment > 1227 [OSHPD 4] Correctional Treatment Centers > 1227.12 Nursing Service Space > 1227.12.6 Seclusion Rooms > 1227.12.6.3 Appendages and Equipment
A113.6 Guidelines for the Seismic Retrofit of Existing Buildings, Parapets
Parapets and exterior wall appendages not conforming to this chapter shall be removed, or stabilized or braced to ensure that the parapets ...
Los Angeles Existing Building Code > A Guidelines for the Seismic Retrofit of Existing Buildings > A113 Detailed System Design Requirements > A113.6 Parapets
A113.6 Guidelines for the Seismic Retrofit of Existing Buildings, Parapets
Parapets and exterior wall appendages not conforming to this chapter shall be removed, or stabilized or braced to ensure that the parapets ...
Los Angeles Existing Building Code > A Guidelines for the Seismic Retrofit of Existing Buildings > A113 Detailed Building System Design Requirements > A113.6 Parapets
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE