1814.1.1 Underpinning and Bracing
JUMP TO FULL CODE CHAPTER
Underpinning piers, walls, piles and footings shall be designed as permanent structural elements and installed in accordance with provisions of this chapter and Chapter 33 and shall be inspected in accordance with the provisions of Chapter 17. Underpinning shall be designed and installed in such manner so as to limit the lateral and vertical displacement of the adjacent structure to permissible values as established in accordance with Section 1814.3. The sequence of installation and the requirements for sheeting, preloading, wedging with steel wedges, jacking or dry packing shall be identified in the design. The design shall take in account the effects on foundation and structure produced by the lateral earth pressure exerted on the underpinning. Lateral support for underpinning, if needed, shall be accounted for during the design of the new construction. The design and construction sequence of temporary lateral supports used prior to the installation of the foundation walls shall be included on the design drawings.
Related Code Sections
1814.1.1 Soils and Foundations, Underpinning and Bracing
Where underpinning is used for the support of adjacent structures, the piers, wall piles or footings shall be installed in such manner so ...
NYC Building Code 2008 > 18 Soils and Foundations > 1814 Underpinning > 1814.1 General > 1814.1.1 Underpinning and Bracing
1814.1.1 Soils and Foundations, Underpinning and Bracing
Underpinning piers, walls, piles and footings shall be designed as permanent structural elements and installed in accordance with provisions ...
NYC Building Code 2014 > 18 Soils and Foundations > 1814 Underpinning and Support of Adjacent Property > 1814.1 General > 1814.1.1 Underpinning and Bracing
Article 11 Foundations, Underpinning
Where support of adjacent structures or properties is required, such support may be provided by underpinning, sheeting, and bracing, or by other ...
3304.1 Safeguards During Construction or Demolition, Scope
to the underpinning or bracing of buildings or structures, in order to safeguard the public and property from such work. Exceptions: Soil ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3304 Soil and Foundation Work > 3304.1 Scope
§27-724 Foundations, Construction Required for or Affecting the Support of Adjacent Properties or Buildings
Except in cases where a proposed excavation will extend less than ten feet below the legally established grade, all underpinning operations ...
NYC 1968 Code (Vol I) > 11 Foundations > 13 Inspection > §27-724 Construction Required for or Affecting the Support of Adjacent Properties or Buildings