P-902.2 Underground Sanitary Drains
JUMP TO FULL CODE CHAPTER
Underground building sanitary drainage within a building and beyond the
building wall shall conform to one of the materials and standards listed in Table P-902.2. Drainage systems for
corrosive industrial wastes shall be of acid-resisting cast iron or other material that is resistant to corrosion and
degradation for the concentrations of chemicals involved.
Note a: Not permitted underground within buildings nor within 10 feet of the building foundation
MATERIAL | STANDARD |
---|---|
Acrylonitrile butadiene styrene (ABS) plastic pipe | ASTM D2661; ASTM F628: CSA B181.1 |
Cast iron pipe | ASTM A 74; ASTM A 888; CISPI 301 |
Coextruded composite ABS DWV schedule 40 IPS pipe (solid) | ASTM F 1488 |
Coextruded composite ABS DWV schedule 40 IPS pipe (cellular core) | ASTM F 1488 |
Coextruded composite PVC DWV schedule 40 IPS (solid) | ASTM F 891; ASTM F 1488 |
Coextruded composite PVC DWV schedule 40 IPS (cellular core) | ASTM F 891; ASTM F 1488 |
Coextruded composite PVC IPS-DR, PS140, PS200 DWV | ASTM F 1488 |
Concrete pipe a | ASTM C 14; ASTM C 76; CSA A 257.1; CSA A 257.2 |
Copper or copper-alloy tubing (Type K, L, M, or DWV) | ASTM B 75: ASTM B 88: ASTM B 251; ASTM B 306 |
Ductile iron | AWWA C 151 |
Polyolefin pipe | ASTM F 1412; CSA B181.3 |
Polyvinyl chloride (PVC) plastic pipe (Type DWV) | ASTM D 2665; ASTM D 2949; CSA B181.2 |
Stainless steel drainage systems, Type 316L | ASME A112.3.1 |
Vitrified clay pipe a | ASTM C 4; ASTM C 700 |
Note a: Not permitted underground within buildings nor within 10 feet of the building foundation
Related Code Sections
P-902.2 Soil and Waste Piping, Underground Sanitary Drains
Underground building sanitary drainage within a building and beyond the
building wall shall conform to one of the materials and standards listed ...
Philadelphia Plumbing Code > 9 Soil and Waste Piping > P-902 Materials > P-902.2 Underground Sanitary Drains
P-411.2 Joints, Below Ground
For repair of underground storm, sanitary or combined main drain lines, a double hub cast
iron fitting shall be permitted with the approval ...
P3010.1 Sanitary Drainage, General
This section shall govern the replacement of existing building sewer and building drain piping by pipe-bursting methods ...
Philadelphia Residential Code > 30 Sanitary Drainage > P3010 Replacement of Underground Building Sewers and Building Drains by Pipe Bursting Methods > P3010.1 General