702.2 Underground Building Sanitary Drainage and Vent Pipe

Jump To Full Code Chapter
Underground building sanitary drainage and vent pipe shall conform to one of the standards listed in Table 702.2.
TABLE 702.2
UNDERGROUND BUILDING DRAINAGE AND VENT PIPE
MATERIAL STANDARD
Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall ASTM D2661; ASTM F628; ASTM F1488; CSA B181.1
Cast-iron pipe ASTM A74; ASTM A888; CISPI 301
Copper or copper-alloy tubing (Type K, L, M or DWV) ASTM B75; ASTM B88; ASTM B251; ASTM B306
Polyethylene (PE) plastic pipe (SDR-PR) ASTM F714
Polyolefin pipe ASTM F714; ASTM F1412; CSA B181.3
Polyvinyl chloride (PVC) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall ASTM D2665; ASTM F891; ASTM F1488; CSA B181.2
Polyvinyl chloride (PVC) plastic pipe with a 3.25-inch O.D. and a solid, cellular core or composite wall ASTM D2949; ASTM F1488
Polyvinylidene fluoride (PVDF) plastic pipe ASTM F1673; CSA B181.3
Stainless steel drainage systems, Type 316L ASME A112.3.1
For SI: 1 inch = 25.4 mm.

Related Code Sections

702.2 Sanitary Drainage, Underground Building Sanitary Drainage and Vent Pipe
Underground building sanitary drainage and vent pipe shall conform to one of the standards listed in Table 702.2. TABLE 702.2 UNDERGROUND ...
702.2 Sanitary Drainage, Underground Building Sanitary Drainage and Vent Pipe
Underground building sanitary drainage and vent pipe shall conform to one of the standards listed in Table 702.2. TABLE 702.2 UNDERGROUND ...
702.2 Sanitary Drainage, Underground Building Sanitary Drainage and Vent Pipe
Underground building sanitary drainage and vent pipe shall conform to one of the standards listed in Table 702.2. TABLE 702.2 UNDERGROUND ...
P3002.1 Sanitary Drainage, Piping Within Buildings
drainage systems, Types 304 and 316L ASME A 112.3.1 For SI: 1 inch = 25.4 mm. TABLE P3002.1(2) UNDERGROUND BUILDING DRAINAGE AND VENT ...