// CODE SNIPPET
1910.430(c)(3) Umbilicals Shall:
JUMP TO FULL CODE CHAPTER
Be marked in 10-ft. increments to 100 feet beginning at the diver's end, and in 50 ft. increments thereafter;
Have a working pressure greater than the pressure equivalent to the maximum depth of the dive (relative to the supply source) plus 100 psi.
Be made of kink-resistant materials; and
Related Code Sections
1910.430(c)(3) Commercial Diving Operations, Umbilicals Shall:
Be marked in 10-ft. increments to 100 feet beginning at the diver's end, and in 50 ft. increments thereafter ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.430 Equipment > 1910.430(c) Breathing Gas Supply Hoses > 1910.430(c)(3) Umbilicals Shall:
1910.430(j)(2) Commercial Diving Operations,
Except when heavy gear is worn or in SCUBA diving, each diver shall wear a safety harness ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.430 Equipment > 1910.430(j) Weights and Harnesses > 1910.430(j)(2)
1910.430(j)(2)(ii) Commercial Diving Operations,
An attachment point for the umbilical to prevent strain on the mask or helmet; and ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.430 Equipment > 1910.430(j) Weights and Harnesses > 1910.430(j)(2) > 1910.430(j)(2)(ii)
1910.430(j) Commercial Diving Operations, Weights and Harnesses
Except when heavy gear is worn, divers shall be equipped with a weight belt or assembly capable of quick release ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.430 Equipment > 1910.430(j) Weights and Harnesses
1910.430 Commercial Diving Operations, Equipment
All employers shall comply with the following requirements, unless otherwise specified ...