• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1303.3 Type of Inspections

California Mechanical Code 2019 > 13 Fuel Gas Piping > 1303.0 Inspection > 1303.3 Type of Inspections
JUMP TO FULL CODE CHAPTER
The Authority Having Jurisdiction shall make the following inspections and either shall approve that portion of the work as completed or shall notify the permit holder wherein the same fails to be in accordance with this code.

1303.3.1 Rough Piping Inspection

This inspection shall be made after gas piping authorized by the permit has been installed before such piping has been covered or concealed, or before fixture or appliance has been attached thereto. This inspection shall include a determination that the gas piping size, material, and installation meet the requirements of this code.

1303.3.2 Final Piping Inspection

This inspection shall be made after piping authorized by the permit has been installed and after portions thereof that are to be covered or concealed are so concealed and before fixture, appliance, or shutoff valve has been attached thereto. This inspection shall comply with Section 1313.1. Test gauges used in conducting tests shall be in accordance with Section 1303.3.3 through Section 1303.3.3.4.

1303.3.3 Test Gauges

Tests required by this code, which are performed utilizing dial gauges, shall be limited to gauges having the following pressure graduations or increments.

1303.3.3.1 Pressure Tests (10 PSI or Less)

Required pressure tests of 10 psi (69 kPa) or less shall be performed with gauges of 0.10 psi (0.69 kPa) increments or less.

1303.3.3.2 Pressure Tests (Greater Than 10 PSI to 100 PSI)

Required pressure tests exceeding 10 psi (69 kPa) but less than or equal to 100 psi (689 kPa) shall be performed with gauges of 1 psi (7 kPa) increments or less.

1303.3.3.3 Pressure Tests (Exceeding 100 PSI)

Required pressure tests exceeding 100 psi (689 kPa) shall be performed with gauges of 2 percent increments or less of the required test pressure.

1303.3.3.4 Pressure Range

Test gauges shall have a pressure range not exceeding twice the test pressure applied.

Related Code Sections


1203.3 Fuel Gas Piping, Type of Inspections
The Authority Having Jurisdiction shall make the following inspections and either shall approve that portion of the work as completed or shall notify ...
California Plumbing Code 2016 > 12 Fuel Gas Piping > 1203.0 Inspection > 1203.3 Type of Inspections
1203.3 Fuel Gas Piping, Type of Inspections
The Authority Having Jurisdiction shall make the following inspections and either shall approve that portion of the work as completed or shall notify ...
California Plumbing Code 2019 > 12 Fuel Gas Piping > 1203.0 Inspection > 1203.3 Type of Inspections
1303.3 Fuel Gas Piping, Type of Inspections
The Authority Having Jurisdiction shall make the following inspections and either shall approve that portion of the work as completed, or shall ...
California Mechanical Code 2016 > 13 Fuel Gas Piping > 1303.0 Inspection > 1303.3 Type of Inspections
1303.3 Fuel Gas Piping, Type of Inspections
The Authority Having Jurisdiction shall make the following inspections and either shall approve that portion of the work as completed or shall notify ...
California Mechanical Code 2019 > 13 Fuel Gas Piping > 1303.0 Inspection > 1303.3 Type of Inspections
R109.1 Scope and Application, Types of Inspections
to be made any necessary inspections and shall either approve that portion of the construction as completed or shall notify the permit holder or his or her ...
California Residential Code 2016 > 1 Scope and Application > R109 Inspections > R109.1 Types of Inspections
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE