B104.3 Type IA and Type IB Construction
JUMP TO FULL CODE CHAPTER
The fire-flow calculation area of buildings constructed of Type IA and Type IB construction shall be the area of the three largest successive floors.
Exception: Fire-flow calculation area for open parking garages shall be determined by the area of the largest floor.
Related Code Sections
B104.3 Fire-Flow Requirements for Buildings, Type IA and Type IB Construction
The fire-flow calculation area of buildings constructed of Type IA and Type IB construction shall be the area of the three largest successive floors ...
California Fire Code 2019 > B Fire-Flow Requirements for Buildings > B104 Fire-Flow Calculation Area > B104.3 Type IA and Type IB Construction
B104.3 Fire-Flow Requirements for Buildings, Type IA and Type IB Construction
The fire-flow calculation area of buildings constructed of Type IA and Type IB construction shall be the area of the three largest successive floors ...
California Fire Code 2016 > B Fire-Flow Requirements for Buildings > B104 Fire-Flow Calculation Area > B104.3 Type IA and Type IB Construction
403.2.1.1 Special Detailed Requirements Based on Use and Occupancy, Type of Construction
not greater than 420 feet (128 000 mm) in building height, the fire-resistance rating of the building elements in Type IA construction shall ...
California Building Code 2016 (Vol 1 & 2) > 4 Special Detailed Requirements Based on Use and Occupancy > 403 High-Rise Buildings and Group I-2 Occupancies Having Occupied Floors Located More Than 75 Feet Above the Lowest Level of Fire Department Vehicle Access > 403.2 Construction > 403.2.1 Reduction in Fire-Resistance Rating > 403.2.1.1 Type of Construction
510.8 General Building Heights and Areas, Group B or M Buildings With Group S-2 Open Parking Garage Above
garage. The building below the horizontal assembly is of Type IA construction. Exception: The building below the horizontal assembly shall ...
California Building Code 2016 (Vol 1 & 2) > 5 General Building Heights and Areas > 510 Special Provisions > 510.8 Group B or M Buildings With Group S-2 Open Parking Garage Above
510.8 General Building Heights and Areas, Group B or M Buildings With Group S-2 Open Parking Garage Above
open parking garage .
The building below the horizontal assembly is of Type IA construction.
Exception: The building below the horizontal ...
California Building Code 2019 (Vol 1 & 2) > 5 General Building Heights and Areas > 510 Special Provisions > 510.8 Group B or M Buildings With Group S-2 Open Parking Garage Above