Where kitchens and kitchenettes are provided in a Type B+NYC dwelling unit or sleeping unit, the primary kitchen or kitchenette shall be constructed in accordance with the kitchen requirements of Section 1003.12 (Kitchen) and 1003.3.2 (Turning Space) of ICC A117.1, including any modifications made by Sections 1107.2.3.1 through 1107.2.3.5 of this code. Secondary kitchens and kitchenettes within the same dwelling unit or sleeping unit shall be required to comply only with Section 1004.12 (Kitchens) of ICC A117.1.
1107.2.3.1 Kitchen Counters
A kitchen counter that is required to comply with Section 1003.12.3.2 or 1003.12.4.2 (Height) of ICC A117.1 shall be permitted to be adjustable or designed to be replaceable as a unit at variable heights between 29 inches and 36 inches (736.6 mm and 914.4 mm), measured from the floor to the top of the work surface. The owner shall adjust or replace such countertop at the time an individual with disabilities takes occupancy of the unit, or within 10 days of the date the request is made by such individual, whichever is later, at the owner's expense.
1107.2.3.2 Appliances in Kitchen and Kitchenette
Appliances in kitchens and kitchenettes shall comply with Section 1003.12.5 (Appliances) of ICC A117.1.
Exception: Where appliances' controls are not in compliance with Section 309.3 (Height) of ICC A117.1, the owner shall replace such appliances with appliances in conformance with Section 309.3 of ICC A117.1 at the time an individual with disabilities takes occupancy of the unit, or within 10 days of the date the request is made by such individual, whichever is later, at the owner's expense. However, the owner shall not be responsible to provide a particular model or type of appliances provided such appliances and controls comply with Sections 1003.12.5 and 309.3 of ICC A117.1.
1107.2.3.3 Refrigerator/Freezers
Combination refrigerators and freezers shall comply with Section 1003.12.5.6 (Refrigerator/Freezer) of ICC A117.1. In addition, where less than 100 percent of storage volume of the freezer is located within 54 inches (1371.6 mm) maximum above the floor, such freezer shall be a self-defrosting type.
Exception: Where refrigerators and freezers are not in compliance with this section, the owner shall replace such appliances with complying appliances at the time an individual with disabilities takes occupancy of the unit, or within 10 days of the date the request is made by such individual, whichever is later, at the owner's expense. However, the owner shall not be responsible to provide a particular model or type of appliances provided such appliances comply with this section.
1107.2.3.4 Cooktops and Ovens
Cooktops and ovens shall comply with Sections 1003.12.5.4 and 1003.12.5.5 of ICC A117.1, respectively. However, oven controls shall not be required to be located on either side of the oven door, provided such controls comply with Section 1003.12.5.5.4 of ICC A117.1. Where double ovens are provided, at least one oven interior and its controls shall comply with Section 309.3 (Height) of ICC A117.1.
1107.2.3.5 Kitchen and Kitchenette Storage
Kitchen storage, kitchen cabinets, drawers, and shelf storage areas, within kitchen and kitchenettes shall comply with Section 905 (Storage Facilities) of ICC A117.1 pursuant to Section 1107.2.3 of this code, except overhead cabinets. In addition, at least one storage shelf or cabinet, mounted above the work surface at 48 inches (1220 mm) maximum above the floor, shall be provided.
Exception: Where the storage shelf or cabinet is not provided in accordance with this section, the owner shall install such storage shelf or cabinet in compliance with this section at the time an individual with disabilities takes occupancy of the unit, or within 10 days of the date the request is made by such individual, whichever is later, at the owner's expense.

Related Code Sections

1107.2.3 Accessibility, Type B+NYC Unit Kitchen and Kitchenette
Where kitchens and kitchenettes are provided in a Type B+NYC dwelling unit or sleeping unit, the primary kitchen or kitchenette shall be constructed ...
1107.2.3 Accessibility, Type B+NYC Unit Kitchen and Kitchenette
Where kitchens and kitchenettes are provided in the Type B+NYC dwelling unit or sleeping unit, the primary kitchen or kitchenette shall ...
1107.2.3.1 Accessibility, Kitchen Counters
A kitchen counter that is required to comply with Section 1003.12.3.2 or 1003.12.4.2 (Height) of ICC A117.1 shall be permitted to be adjustable ...
1107.2.3.3 Accessibility, Refrigerator/Freezers
percent of storage volume of the freezer is located within 54 inches (1371.6 mm) maximum above the floor, such freezer shall be a self-defrosting type ...
1107.2.3.3 Accessibility, Refrigerator/Freezers
percent of storage volume of the freezer is located within 54 inches (1372 mm) maximum above the floor, such freezer shall be a self-defrosting type ...