1910.211(b)(3) Type 6 Straight Cup Wheels
JUMP TO FULL CODE CHAPTER
Type 6 straight cup wheels means wheels having diameter, thickness, hole size, rim thickness, and back thickness dimensions. Grinding is always performed on rim face, W dimension.
LIMITATION: Minimum back thickness, E dimension, should not be less than one-fourth T dimension. In addition, when unthreaded hole wheels are specified, the inside flat, K dimension, must be large enough to accommodate a suitable flange.
FIGURE NO. O-3. - TYPE 6 STRAIGHT CUP WHEELS
Side grinding wheel having a diameter, thickness and hole with one side straight or flat and the opposite side recessed. This type, however, differs from Type 5 in that the grinding is performed on the wall of the abrasive created by the difference between the diameter of the recess and the outside diameter of the wheel. Therefore, the wall dimension "W" takes precedence over the diameter of the recess as an essential intermediate dimension to describe this shape type.
LIMITATION: Minimum back thickness, E dimension, should not be less than one-fourth T dimension. In addition, when unthreaded hole wheels are specified, the inside flat, K dimension, must be large enough to accommodate a suitable flange.
Side grinding wheel having a diameter, thickness and hole with one side straight or flat and the opposite side recessed. This type, however, differs from Type 5 in that the grinding is performed on the wall of the abrasive created by the difference between the diameter of the recess and the outside diameter of the wheel. Therefore, the wall dimension "W" takes precedence over the diameter of the recess as an essential intermediate dimension to describe this shape type.
Related Code Sections
1910.211(b)(3) Machinery and Machine Guarding, Type 6 Straight Cup Wheels
Type 6 straight cup wheels means wheels having diameter, thickness, hole size, rim thickness, and back thickness dimensions. Grinding is always ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.211 Definitions > 1910.211(b) > 1910.211(b)(3) Type 6 Straight Cup Wheels
1910.241(b)(9) Hand and Portable Powered Tools and Other Hand-Held Equipment, Type 6 Straight Cup Wheels
Type 6 cup wheels have diameter, thickness, hole size, rim thickness, and back thickness dimensions. Grinding is always performed on rim face, W ...
OSHA 1910 General Industry > P Hand and Portable Powered Tools and Other Hand-Held Equipment > 1910.241 Definitions > 1910.241(b) Abrasive Wheel Terms > 1910.241(b)(9) Type 6 Straight Cup Wheels
1910.211 Machinery and Machine Guarding, Definitions
Type 6 straight cup wheels means wheels having diameter, thickness, hole size, rim thickness, and back thickness dimensions ...
1910.215(b)(1) Machinery and Machine Guarding, Cup Wheels
Cup wheels (Types 6 and 11) shall be protected ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.215 Abrasive Wheel Machinery > 1910.215(b) Guarding of Abrasive Wheel Machinery > 1910.215(b)(1) Cup Wheels
1910.243(c)(2) Hand and Portable Powered Tools and Other Hand-Held Equipment, Cup Wheels
Cup wheels (Types 6 and 11) shall be protected ...
OSHA 1910 General Industry > P Hand and Portable Powered Tools and Other Hand-Held Equipment > 1910.243 Guarding of Portable Powered Tools > 1910.243(c) Portable Abrasive Wheels > 1910.243(c)(2) Cup Wheels