• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

104-335 Type 5 Street Wall Location

NYC Zoning Resolution > X Special Purpose Districts > 4 - Special Manhattanville Mixed Use District (MMU) > 104-30 Special Height and Setback Requirements > 104-33 Mandatory Street Walls > 104-335 Type 5 Street Wall Location
JUMP TO FULL CODE CHAPTER

Type 5 street walls, as shown on Map 4 in Appendix A of this Chapter, shall comply with the provisions of paragraph (a) or (b) of this Section:

(a)        The street wall shall be located within two feet of the street line or the mandatory widened sidewalk line, as applicable, and shall rise without setback to a minimum height of 45 feet or the height of the building, whichever is less. Such required street walls shall extend along at least 50 percent of the length of the street line or the mandatory widened sidewalk line of the Parcel, as applicable; or

(b)        Where the lower street wall is set back from the upper street wall, the provisions of Section 104-334 (Type 4 street wall location) shall apply.

No street wall location regulations shall apply to the remaining 50 percent of the street frontage of a Parcel.

Related Code Sections


903.1.2 Fire Protection Systems, Construction Documents
location and size of water supplies and the location, spacing, number, and type of sprinkler heads to be used, with approximate location and size of all ...
NYC Building Code 2008 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.1 General > 903.1.2 Construction Documents
912.2 Fire Protection Systems, Location
building wall or fraction thereof facing upon each street or public space ...
NYC Building Code 2014 > 9 Fire Protection Systems > 912 Fire Department Connections > 912.2 Location
§27-376 Means of Egress, Exterior Stairs
towers shall open on a street or yard, or on a court open vertically to the sky for its full height, having a minimum net area of one hundred five ...
NYC 1968 Code (Vol I) > 6 Means of Egress > 5 Access Requirements and Exit Types > §27-376 Exterior Stairs
E.5 Meters and Gas Service Piping, Gas Service Piping Connections
Gas service piping connections shall comply with the following: Gas service piping shall be fitted with a gas service line valve, the valve located ...
NYC Fuel Gas Code 2014 > E Meters and Gas Service Piping > E.5 Gas Service Piping Connections
406.7.3 Special Detailed Requirements Based on Use and Occupancy, Permit Required
be accompanied by a plan exhibiting the following:   1. Dimensions of the lot and its location in relation to adjoining streets ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor Vehicle-Related Occupancies > 406.7 Open Parking Lots > 406.7.3 Permit Required
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE