104-333 Type 3 Street Wall Location
JUMP TO FULL CODE CHAPTER
Type 3 street walls, as shown on Map 4 in Appendix A of this Chapter, shall comply with the provisions of this Section.
(a) The upper street wall shall be located within two feet of the 12th Avenue mandatory widened sidewalk line, and shall extend along no more than 70 percent of the length of the mandatory widened sidewalk line of the Parcel. Any upper street wall located on the remaining portion of the street frontage of the Parcel shall be set back from the 12th Avenue widened sidewalk line by a minimum distance of either:
(1) 20 feet, if such setback area faces both 12th Avenue and a narrow street; or
(2) 10 feet, if such setback area faces only 12th Avenue.
(b) The lower street wall shall be located at the same distance from the mandatory widened sidewalk line, or set back not more than 10 feet from the upper street wall required pursuant to paragraph (a) of this Section, and shall extend along at least 80 percent of the length of such required upper street wall. No street wall location regulations shall apply to the remaining portion of the lower street wall frontage of a Parcel.
(c) The street wall provisions of this Section may apply along a narrow street within 100 feet of its intersection of a wide street.
Related Code Sections
903.1.2 Fire Protection Systems, Construction Documents
be necessary for the evaluation of the system. 3. The location, number, and type of any electrical or automatic devices or alarms ...
NYC Building Code 2008 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.1 General > 903.1.2 Construction Documents
912.2 Fire Protection Systems, Location
a building faces on three streets or public spaces, one Fire Department connection shall be provided for each 300 feet (91 140 mm) of building wall ...
NYC Building Code 2014 > 9 Fire Protection Systems > 912 Fire Department Connections > 912.2 Location
912.2 Fire Protection Systems, Location
a building faces on three streets or public spaces, one Fire Department connection shall be provided for each 300 feet (91 140 mm) of building wall ...
NYC Building Code 2022 > 9 Fire Protection Systems > 912 Fire Department Connections > 912.2 Location
Article 5 General Building Restrictions [PDF] (page 7)
wall of such structures may be omitted, except on any side which faces and is located within fifteen feet of a lot line other than a street line ...
1027.5 Means of Egress, Location
story above grade plane located
at the street wall and terminating at the street are permitted to be located within 10 feet (3048 mm)
of adjacent lot ...
NYC Building Code 2022 > 10 Means of Egress > 1027 Exterior Exit Stairways and Ramps > 1027.5 Location