1014.2.4.4 Two Intervening Rooms
JUMP TO FULL CODE CHAPTER
For rooms other than patient sleeping rooms located within a suite, exit access travel from within the suite shall be permitted through two intervening rooms where the travel distance to the exit access door is not greater than 50 feet (15 240 mm).
Related Code Sections
1014.2.4.4 Means of Egress, Two Intervening Rooms
For rooms other than patient sleeping rooms located within a suite, exit access travel from within the suite shall be permitted through two ...
NYC Building Code 2014 > 10 Means of Egress > 1014 Exit Access > 1014.2 Egress Through Intervening Spaces > 1014.2.4 Suites in Areas Other Than Patient Sleeping Areas > 1014.2.4.4 Two Intervening Rooms
1013.2.2 Means of Egress, Group I-2
the suite to the exit access door is not greater than 100 feet (30 480 mm) and are permitted to have two intervening rooms where the travel distance ...
NYC Building Code 2008 > 10 Means of Egress > 1013 Exit Access > 1013.2 Egress Through Intervening Spaces > 1013.2.2 Group I-2
1014.2.3 Means of Egress, Suites in Patient Sleeping Areas
Patient sleeping areas in Group I-2 occupancies shall be permitted to be divided into suites with one intervening room if one of the following ...
NYC Building Code 2014 > 10 Means of Egress > 1014 Exit Access > 1014.2 Egress Through Intervening Spaces > 1014.2.3 Suites in Patient Sleeping Areas
§27-419 Special Uses and Occupancies, Enclosure
rating. Entrance to such enclosed rooms shall be from the outdoors, or through an intervening vestibule constructed of materials having a two hour ...
NYC 1968 Code (Vol I) > 7 Special Uses and Occupancies > 5 Boiler and Furnace Rooms > §27-419 Enclosure
1014.2.4.3 Means of Egress, One Intervening Room
For rooms other than patient sleeping rooms, suites of rooms are permitted to have one intervening room if the travel distance within the suite ...
NYC Building Code 2014 > 10 Means of Egress > 1014 Exit Access > 1014.2 Egress Through Intervening Spaces > 1014.2.4 Suites in Areas Other Than Patient Sleeping Areas > 1014.2.4.3 One Intervening Room