// CODE SNIPPET
610.3.2 Two-Family Dwellings, Multiple Single-Family Dwellings (Townhouses), and Buildings Owned as Condominiums or Cooperatives and Containing Dwelling Units
JUMP TO FULL CODE CHAPTER
Within each dwelling unit:
A carbon monoxide alarm shall be provided on every story containing a sleeping area, within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm.
A carbon monoxide alarm shall be provided on every story that contains a carbon monoxide source.
Within each dwelling unit, a carbon monoxide alarm shall be provided on the lowest story containing a sleeping area, within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm.
Related Code Sections
610.3.2 Building Services and Systems, Two-Family Dwellings, Multiple Single-Family Dwellings (Townhouses), and Buildings Owned as Condominiums or Cooperatives and Containing Dwelling Units
Within each dwelling unit: A carbon monoxide alarm ...
2010 Fire Code of NY > 6 Building Services and Systems > 610 Carbon Monoxide Alarms > 610.3 Required Locations > 610.3.2 Two-Family Dwellings, Multiple Single-Family Dwellings (Townhouses), and Buildings Owned as Condominiums or Cooperatives and Containing Dwelling Units
Section 610 Building Services and Systems, Carbon Monoxide Alarms
, and their components, in new and existing one- and two-family dwellings; multiple single-family dwellings (townhouses); buildings owned as condominiums ...
402.2.12 Residential Energy Efficiency, Tenant Separation Walls (Mandatory)
Fire separations between dwelling units in two-family dwellings and multiple single-family dwellings (townhouses) shall be insulated to no less than ...
2010 Energy Conservation Code of NY > 4 Residential Energy Efficiency > 402 Building Thermal Envelope > 402.2 Specific Insulation Requirements (Prescriptive) > 402.2.12 Tenant Separation Walls (Mandatory)
R402.4.6 [RE] Residential Energy Efficiency, Tenant Separation Walls (Mandatory)
Fire separations between dwelling units in two-family dwellings and multiple single-family dwellings ( townhouses ) shall be insulated to no less ...
2020 Energy Conservation Code of NYS > 4 [RE] Residential Energy Efficiency > R402 Building Thermal Envelope > R402.4 Air Leakage (Mandatory) > R402.4.6 Tenant Separation Walls (Mandatory)
N1102.2.12 Energy Efficiency, Tenant Separation Walls (Mandatory)
Fire-resistance-rated construction separating dwelling units in two-family dwellings and multiple single-family dwellings (townhouses) shall ...
2010 Residential Code of NY > 11 Energy Efficiency > N1102 Building Thermal Envelope > N1102.2 Specific Insulation Requirements (Prescriptive) > N1102.2.12 Tenant Separation Walls (Mandatory)