• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3105F.3.4 Tsunami

Los Angeles Building Code > 31F [SLC] Marine Oil Terminals > 3105F Mooring and Berthing Analysis and Design > 3105F.3 Wave, Passing Vessel, Seiche and Tsunami > 3105F.3.4 Tsunami
JUMP TO FULL CODE CHAPTER

Run-up and current velocity shall be considered in the tsunami assessment. Section 3103F.5.7 and Table 31F-3-6 provides run-up values for the San Francisco Bay area, Los Angeles/Long Beach Harbors and Port Hueneme.

Related Code Sections


3103F.5.7 [SLC] Marine Oil Terminals, Tsunamis
A tsunami may be generated by an earthquake or a subsea or coastal landslide, which may induce large wave heights and excessive currents. The large ...
Los Angeles Building Code > 31F [SLC] Marine Oil Terminals > 3103F Structural Loading Criteria > 3103F.5 Mooring Loads on Vessels > 3103F.5.7 Tsunamis
3105F.3.4 [SLC] Marine Oil Terminals, Tsunami
Run-up and current velocity shall be considered in the tsunami assessment. Section 3103F.5.7 and Table 31F-3-6 provides run-up values for the San ...
Los Angeles Building Code > 31F [SLC] Marine Oil Terminals > 3105F Mooring and Berthing Analysis and Design > 3105F.3 Wave, Passing Vessel, Seiche and Tsunami > 3105F.3.4 Tsunami
Section 1615 Structural Design, Tsunami Loads
The design and construction of Risk Category III and IV buildings and structures located in the Tsunami Design Zones defined in the Tsunami Design ...
Los Angeles Building Code > 16 Structural Design > 1615 Tsunami Loads
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE