// CODE SNIPPET
2303.4.1.4 Truss Designer
JUMP TO FULL CODE CHAPTER
The individual or organization responsible for the design of trusses.
Where required by the registered design professional, the building official or the statutes of the jurisdiction in which the project is to be constructed, each individual truss design drawing shall bear the seal and signature of the truss designer.
Exceptions:
- Where a cover sheet and truss index sheet are combined into a single sheet and attached to the set of truss design drawings, the single cover/truss index sheet is the only document required to be signed and sealed by the truss designer.
- When a cover sheet and a truss index sheet are separately provided and attached to the set of truss design drawings, the cover sheet and the truss index sheet are the only documents required to be signed and sealed by the truss designer.
Related Code Sections
2211.1.3 Steel, Truss Design
The truss design drawings shall conform to the requirements of Section I1 of AISI S202 ...
Building Code 2018 of Utah > 22 Steel > 2211 Cold-Formed Steel Light-Frame Construction > 2211.1 Structural Framing > 2211.1.3 Truss Design
2211.3 Steel, Truss Design
Cold-formed steel trusses shall be designed in accordance with AISI S214, Sections 2211.3.1 through 2211.3.4 and accepted engineering practice ...
Building Code 2015 of Utah > 22 Steel > 2211 Cold-Formed Steel Light-Frame Construction > 2211.3 Truss Design
2303.4.1.4 Wood, Truss Designer
The individual or organization responsible for the design of trusses ...
Building Code 2015 of Utah > 23 Wood > 2303 Minimum Standards and Quality > 2303.4 Trusses > 2303.4.1 Design > 2303.4.1.4 Truss Designer
2303.4.1.4 Wood, Truss Designer
The individual or organization responsible for the design of trusses ...
Building Code 2018 of Utah > 23 Wood > 2303 Minimum Standards and Quality > 2303.4 Trusses > 2303.4.1 Design > 2303.4.1.4 Truss Designer
2303.4.1.4.1 Wood, Truss Design Drawings
is to be constructed, each individual truss design drawing shall bear the seal and signature of the truss designer. Exceptions: Where a cover sheet ...
Building Code 2018 of Utah > 23 Wood > 2303 Minimum Standards and Quality > 2303.4 Trusses > 2303.4.1 Design > 2303.4.1.4 Truss Designer > 2303.4.1.4.1 Truss Design Drawings